Frigidaire FGEF304DKFE Installation Instructions Manual page 5

30"
Hide thumbs Also See for FGEF304DKFE:
Table of Contents

Advertisement

Available languages

Available languages

Three Conductor
Wire Connection
to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 7):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored
terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal) (see figure 7).
3. Replace the terminal cover and replace the screws.
Silver Colored Terminal
Red Wire
Four Conductor
Wire Connection
to Range
Where local codes does NOT permit connection
of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 8):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure
8).
4. Connect the neutral of the copper power supply
cord to the center silver-colored
terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Replace the terminal cover and replace the screws.
Terminal Block
Silver Colored Terminal
Terminal
Block
Red
Wire
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
Location.
To 240 V
Receptacle
Figure 7
1 1/8" (2.9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3.5 cm) Dia. Cord
Kit Hole.
Black Wir,
1 1/8" (2.9cm)
Dia.
Connection
Hole. Punch
Out Knockout f,
1 3/8" (3.5cm)
Dia. Cord Kit
Hole.
A User Sup_
Strain-relief Must
Be Installed at
This Location
To 240 V Receptacle
NOTE: Be sure to remove the
supplied grounding strap.
Figure 8

Advertisement