ADDING
ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
• Preassemble 4" elbow with 4" duct. Wrap duct tape
Ground joint.
• Insert duct assembly, elbow first, through the side
opening and connect the elbow to the dryer internal
duct.
-&CAUTION:
Be sure not to pull o r damage the
electrical wires inside the drger when inserting the duct.
EXHAUST
CAN
BEADDEDTO
LEFT O R RIGHT S IDE
• Apply duct tape as shown on the joint between the
dryer internal duct and the elbow.
DUCT
CAUTION:
Internal duct joints must be
secured with tape, otherwise
theg mag separate and cause a
safetg hazard.
ADDING
ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
• Insert the elbow through the rear opening and connect
it to the dryer internal duct.
• Apply duct tope on the joint between the dryer internal
duct and elbow, as shown above.
CAUTION:
Internal
duct joints
must
be secured
with tape,
otherwise
they may separate
and cause a
safety
hazard.
ADDING COVER PLATE TO REAR OF
CABINET (SIDES AND BOTTOM EXHAUST)
PLATE
{KIT WE1M454)
Connect standard metal elbows and ducts to complete
the exhaust system. Cover back opening with a plate (Kit
WEllV]454) available from your local service provider. Place
dryer in final location.
-_WARNING-NEVER
LEAVE THE
BACK OPENING WITHOUT
THE PLATE
(Kit WEIM454).
REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY
IMPORTANT PRODUCT NOTIFICATIONS.
Please go to www.GEAppliances.com
or mail in
your product registration