Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Installation
Instructions
Electric
Dryer
01
I
Questions on Installation? Coil: 800.GE.CARES
(US)
|
or visit our Web
siteat:www.GEAppliances.com
(US)
l
BEFORE YOU BEGIN
Read these instructions
completely and
carefully.
• IMPORTANT-
save
these
instructions
for local inspector's use.
• iMPORTANT-
Observe all governing
codes and ordinances.
, Note to Installer - Be sure to leave these
instructions with the customer.
, Note to Customer-
Keep these instructions
with your Owner's Manual for future
reference.
. Before the old dryer is removed from service
or discarded, remove the dryer door.
, Service information and the wiring diagram
are located in the control console.
, Do not allow children on or in the appliance.
Close supervision of children isnecessa]ry
when the appliance is used near children.
Install the dryer where the temperature is
above 50°F for satisfactory operation of the
dryer control system.
Product failure due to improper installation
is not covered under the Warranty.
I WARNING
RISK OF FIRE
, To reduce the risk of severe injury or death, follow all installation
instructions.
Clothes dryer installation must be performed by a]qualified insta]ller.
Install the clothes dryer according to these instructions and in accordance
with local codes.
This dryer must be exhausted to the outdoors.
Use only rigid metal 4" diameter ductwork inside the dryer cabinet and use
only ULapproved transition ducting between the dryer and the home duct.
DO NOT install a] clothes dryer with flexible plastic ducting materials. If
flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed
and installed in accordance with the instructions found in "Connecting
The Dryer To House Vent" on pages 4-5 of this manual. Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These
conditions will obstruct dryer airflow and increase the risk of fire.
Do not install or store this appliance in any location where it could be
exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions
with the customer).
NOTE: Installation
end
service
of this
dryer
requires
basic
mechanical
and electrical
skills. It is your responsibility
to contact
o qualified
installer
to make the electrical
connections.
TOOLSYOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
4"DIA. M ETAL DUCT
(RECOMMENDED}
MATERIALS YOUWILL NEED
4"DIA, F LEXIBLE
METAL (SEMPRIGID)
UL LISTED
TRANSITION
DUCT
(IF NEEDED)
KIT WXOBX!O077
(INCLUDES
2ELBOWS}
4"DIA. FLEXIBLE
METAL (FOIL TYPE)
UL LISTED
TRANSITION
DUCT
(IF NEEDED,)
#'DUCT
%
4"DIA, M ETAL
ELBOW
CLAMPS
(2)
EXHAUST
HOOD
OR
#'SPRING
CLAMPS
(2)
DUCTTAPE
GLOVES
%
SAFETY
GLASSES
3/4" S TRAIN
RELIEF
ULRECOGNIZED
DRYER
POWER
CORD K IT
(NOT P ROVIDED
WITH DRYER)
UL RATED
!20/240V,30A
WITH 3OR 4PRONGS,
IDENTIFY
THE P LUG
TYPE A SPER T HE
HOUSE RECEPTACLE
BEFORE
PURCHASING
LINE C ORD,
Minimum
Clearance
Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides, 1 in. front and 3 in. rear.
Consideration must be given to provide adequate clearance for installation and service.
Printedin Mexico
234D2008PO01
31-16714
03-13
GE

Advertisement

loading

Summary of Contents for GE GFDN110ED1WW

  • Page 1 Installation Electric Dryer Instructions or visit our Web Questions on Installation? Coil: 800.GE.CARES siteat:www.GEAppliances.com (US) (US) BEFORE YOU BEGIN I WARNING RISK OF FIRE Read these instructions completely and , To reduce the risk of severe injury or death, follow all installation carefully.
  • Page 2 Installation Instructions CONNECTING DRYER USING 4-WIRE [iIPREPARING FOR INSTALLATION NEW DRYER CONNECTION (MUST BE USED FOR MOBILE HONE INSTALLATION) TIP: Install your dryer before installing your washer. This will allow better access when installing dryer exhaust. NOTE: Since January 1,1996, the National Electric code requires that the new constructions utilize a 4-wire...
  • Page 3 Installation Instructions CONNECTING DRYER USING 3-WIRE CONNECTION S-wire Connection tf required, by local code, install external ground (not provided) to grounded metal, cold water pipe, or other established ground Not for use in Canada. determined by a qualified electrician. DO NOTuse for Mobile Home Installations. Wire according to the terminal block illustration that matches NOT for use on new construction.
  • Page 4: Exhaust Information

    Installation Instructions [-3] EXHAUST INFORMATION EXHAUST LENGTH WARNÁNG -IN CANADA ANDINTHE RECOMMENDED lvtAXIiVlUivtLENGTH UNITED STATES, THE REQUIRED EXHAUST DUCT Exhaust Hood Types DIAMETER IS 4 in I102mm). DO NOT USE DUCT Use only for short Recommended run installations LONGER THAN SPECIFIED EXHAUST 4"...
  • Page 5 nstructions Installation STANDARD REAR EXHAUST EXHAUST SYSTEM CHECK LiST(cont.) (Vented at floorlevel) SEPARATIONOF TURNS For best performance, separate all turns by at least 4 ft. of For straight line installation, connect straight duct, including distance between last turn and exhaust the dryer exhaust to the external hood.
  • Page 6: Alcove Or Closet Installation

    Installation Instructions For best drying performance , For many applications, installing elbows at both the dryer 1. Slide one end of the duct over the clothes dryer outlet and the wall is highly recommended (see illustrations pipe. below). Elbows allow the dryer to sit close to the wall 2.
  • Page 7 Installation instructions FIXING HOLE _7 BATHROOM OR BEDROOM INSTALLATION .The dryer MUST be ventedtotheoutdoors. See EXHAUST INFORMATION section 3 & 4. . The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL _"...
  • Page 8 Installation instructions ADDING ELBOW AND DUCT FOR ADDING COVER PLATE TO REAR OF EXHAUST TO LEFT OR RIGHT SIDE OF CABINET (SIDES AND BOTTOM EXHAUST) CABINET . Preassemble 4" elbow with 4" duct. Wrap duct tape around joint. * Insert duct assembly, elbow first, through the side opening and connect the elbow to the dryer internal duct.
  • Page 9: Materiales Necesarios

    Secadora El@ctrica Instrucciones de instalaci6n instalaci6n? 2.Preguntas sobre Llame al: 1-800-GECARES (EE.UU.) o visite nuestro sitio Web en: www.GEAppliances.com (EE.UU.) ANTES DE COMENZAR ADVERTENCIA RIESGO DE INCENDIO Lea estos instrucciones por completo y con . Peru reducir el riesgo de una lesi6n grove o de muerte, cumpla con todas detenimiento.
  • Page 10 de instoloci6n Instrucciones [1]PREPARACI6N PARA LA INSTALACI6N COMO CONE CTAR LA SECADORA USANDO UNA CONE×ION DE4 CABLES(DEBEUTILIZARSE DE UNA SECADORA NUEVA EN INSTALAClONES DE CASAS H6VILES) CONSEJO: Instale su secadora antes de instalar lavadora. Esto permitir6 un mejor acceso cuando NOTA: Desde el I de enero de 1996, el C6digo ElSctrico Nacional...
  • Page 11 Instrucciones de instalaci6n C6MO CONECTAR LA SECADORA UTILIZANDO UNA CONE×I6N DE 3 CABLES Conexi6n de 3 cables Si asi Io requirieran losc6digos locales,instaleuna conexi6n a tierra externa (no provista)a metal con conexi6n a tierra, tuberias de NO usar en Canad6. agua fria con conexi6n a tierra u otra conexi6na tierra establecida NO usar en instalaciones en casas m6viles.
  • Page 12 instalaci6n Instrucciones INFORMACI6N DESALIDA LONGITUDDESAUDA ADVERTENCIA CANADAY LONGITUD MAXllVlA RECOMENDADA LOS ESTADOS UNIDOS, EL DIAMETRO Tipos de campana de salida Utilizar s61o en instalaciones Recomendado DE CONDUCTO DE SALIDA REQUERIDO de travecto corto 4" DIA. ES DE 4 PULG. (I02 mm). NO UTILICE UN CONDUCTO DE UNA LONGITUD MAYOR A LA ESPECIFICADA EN LA TABLA DE ..
  • Page 13 Instrucciones de instalaci6n Losconductos m6s largos acumulan pelusa, Io que genera un LISTA DE CONTROL DEL SISTEMA DE SALIDA riesgo potencial de incendio. (cont .) . Nunca instale un filtro dentro o sobre el conducto de salida. . Las cubiertas de pared deben instalarse por Io menos a 12" Esto provocarc_ la acumulaci6n de pelusas, Io que genera sobre el nivel del suelo o cualquier otra obstrucci6n con la un riesgo potencial de incendio.
  • Page 14 Instrucciones de instalaci6n *Nunca instale conductos de metal flexibles en paredes, NOTA: LOS CODOS EVITAN QUE LOS cielorrasos, pisos u otros espacios cerrados. CONDUCTOS SE DOBLEN O CAIGAN. La Iongitud total del conducto de metal flexible no deber6 C6MO CON ECTAR LA SECADORA A LA superar los 8 pies (2.4m).
  • Page 15 de instalaci6n Instrucciones r6] INSTALACION EN NICHO O EN CLOSET rf0]SALIDA DE LA SECADORA HACIA LA DERECHA, IZQUIERDA O PARTE .Su secadora instalarse en un nicho puede o closet, INFERIOR DEL GABINETE coma se indica en la etiqueta de la parte trasera del aparato.
  • Page 16 Instrucciones de instalaci6n C6MO AGREGAR CONDUCTOS NUEVOS C6MO AGREGARUN CODO DE SALIDA A ORIFICIO TRAVI_SDE LA PARTEINFERIOR DEL GABINETE DE MONTAJE PORCION "A" Introduzca el codo a trav6s de la abertura trasera con6ctelo al conducto interno de la secadora. Aplique cinta aislante en la junta...

This manual is also suitable for:

Gfdn120ed1wwGfds140ed1ww