Installation
Instructions
Electric Dryer
10
Questions
on Installation?
Call: 1-800-GECARES
(US)
or Visit our Web site at: www.GEAppliances.com
(US)
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
• IN PORTANT- save
these instructions
for local inspector's use.
• IMPORTANT-
Observe all governing
codes and ordinances.
• Note to Installer - Be sure to leave these
instructions with the customer.
• Note to Customer - Keep these instructions
with your Use and Care Book for future
reference.
• Before the old dryer is removed from service
or discarded, remove the dryer door.
• Service information and the wiring diagram
are located in the control console.
• Do not allow children on or in the appliance.
Close supervision of children is
necessary when the appliance is used
near children.
• Install the dryer where the temperature
is above 50°F for satisfactory operation of
the dryer control system.
ZkWARNING
RISK OF FIRE
•To reduce the risk of severe injury or death, follow all installation
instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in
accordance with local codes.
• This dryer must be exhausted to the outdoors.
• Use only rigid metal 4" diameter ductwork inside the dryer cabinet and use
only UL approved transition ducting between the dryer and the home duct.
• DO NOT install a clothes dryer with flexible plastic ducting materials. If
flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed
and installed in accordance with the instructions found in "Connecting
The Dryer To House Vent" on pages 4-5 of this manual. Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These
conditions will obstruct dryer airflow and increase the risk of fire.
• Do not install or store this appliance in any location where it could be
exposed to water and or weather.
• Save these instructions. (Installers: Be sure to leave these instructions
with the customer).
NOTE: Installation
and service of this dryer requires
basic
mechanical
and electrical
skills. It is your responsibility
to
contact
a qualified
installer
to make the electrical
connections.
I
Step 1
Step 2
Step 5
Step 4
Step 5
Step 6
TOOLSYOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE S CREWDRIVER
PHILLIPS SCREWDRIVER
MATERIALS YOUWILL NEED
4"DIA. M ETAL DUCT
(RECOMMENDED)
)
4"DIA. F LEXIBLE
METAL(SEMI-RIGID)
UL LISTED
TRANSITION
DUCT
(IF NEEDED)
KIT WXO8XIO077
(INCLUDES
2ELBOWS)
4"DIA. FLEXIBLE
METAL(FOILTYPE)
UL LISTED
TRANSITION
DUCT
(IF NEEDED.)
4"DUCT
%
4"DIA. M ETAL
ELBOW
CLAMPS
(2)
EXHAUST
HOOD
OR
4"SPRING
CLAMPS
(2)
SAFETY
GLASSES
_
3/4" S TRAIN
DUCTTAPE
GLOVES
RELIEF
ULRECOGNIZED
4"COVER PLATE (IFNEEDED
(KiTWEIM454)
DRYER
POWER
CORD K IT
(NOT P ROVIDED
WITH DRYER)
UL RATED
120/240V,]OA
WITH 30R4PRONGS.
IDENTIFY
THE P LUG
TYPE A SPER T HE
HOUSE RECEPTACLE
BEFORE
PURCHASING
LINE C ORD.
Prepare the area and exhaust for installation of new dryer
(see section 1).
Check and ensure the existing external exhaust is clean (see
section 1) and meets attached installation specifications (see
section 5).
Remove the foam shipping pads (see section 1).
Move the dryer to the desired location.
Connect the power supply (see section 2).
Connect the external exhaust (see section 4).
Step 7 Level y our dryer (seesection 5).
Step
8 Checkthe
operation
of the power supply and
venting.
Step9 Placethe owners manual and the installationinstructions in
a location wherethey will be noticed bythe owner.
Foralcove or closetinstallation, seesection6.
Forbathroom or bedroominstallation, seesection7.
Formobileor manufactured home, seesection8.
Forsideor bottom exhaust, seesection9.
31-16629-1
03-11
GE
234D1052PO03

Advertisement

loading

Summary of Contents for GE GFDS355EL1MS

  • Page 1 Installation Electric Dryer Instructions Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.GEAppliances.com (US) BEFORE YOU BEGIN ZkWARNING RISK OF FIRE Read these instructions completely and •To reduce the risk of severe injury or death, follow all installation carefully.
  • Page 2 Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides, 1 in. front and 3 in. rear. Consideration must be given to provide adequate clearance for installation and service. CONNECTING DRYER USING 4-WIRE PREPARING FOR INSTALLATION...
  • Page 3 Installation Instructions CONNECTING DRYER USING 3-WIRE 131EXHAUST INFORMATION CONNECTION ,AWARNING -IN CANADA AND INTHE IFREQUIRED, BYLOCAL CODE, INS TALL EXTERNAL GROUND UNITED STATES, THE REQUIRED EXHAUST (NOT P ROVIDED)TO GROUNDED DUCT DIAMETER IS 4in (102ram). DO NOT USE ME TALCOLDWATER P IPE, OR GREEN GROUND OTHER ESTABLISHED...
  • Page 4 Installation nstructions STANDARD REAR EXHAUST SEALING OF JOINTS • All joints should be tight to avoid leaks. The male end of (Vented at floor level) each section of duct must point away from the dryer. • The duct shall not be assembled with screws or other For straight line installation, connect the dryer exhaust to the external...
  • Page 5 Installation Instructions • For many applications, installing elbows at both the dryer [51 LEVELING AND STABILIZING YOUR and the wall is highly recommended (see illustrations DRYER below). Elbows allow the dryer to sit close to the wall Stand the dryer upright near the final location and adjust without kinking and or crushing the transition duct,...
  • Page 6 Installation Instructions TAB LOCATION BATHROOM OR BEDROOM INSTALLATION • The dryer MUST be vented to the outdoors. See EXHAUST INFORMATION section ] & 4. • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL BEND T AB CODE, ANSI/NFPA NO.
  • Page 7 Installation Instructions ADDING ELBOW AND DUCT FOR ADDING COVER PLATE TO REAR OF EXHAUST TO LEFT OR RIGHT SIDE OF CABINET (SIDES AND BOTTOM EXHAUST) CABINET • Preossemble 4" elbow with 4" duct. Wrop duct tope around joint. • Insert duct ossembly, elbow first, through the side opening ond connect the elbow to the dryer internol duct.
  • Page 8: Antes De Comenzar

    Para instalaci6nen halos o dormitorios,ver secci6n7. Paso 5 Conecte el suministro de energia (ver secci6n 2). Paracasas m6vileso prefabricadas,ver secci6n8. Paso 6 Conecte la salida al exterior (ver secci6n 4). Parasalidas lateraleso par la parte inferior,ver secci6n9. 31-16629-103-ii GE 234DI052P003...
  • Page 9 Instrucciones de instalaci6n Espacio minimo diferente a instalaci6n en nichos o closets Losespacioslibresm[nimosrespectode superficiescombustiblesy de aberturasde aire son:Espaciode 0 pulg.a ambos lados,1 pulg.en el frentey 3 pulg.en la partetrasera. Debetenerseen cuenta un espaciolibre adecuadopara un funcionamientoy reparaci6ncorrectos COMO CONECTAR LA SECADORA USAN- ITI PREPARACION PARA LA INSTALACION DO UNA CONE×I6N DE 4 CABLES (DEBE...
  • Page 10 Instrucciones de instalaci6n C6MO CONECTAR LA SECADORA UTILI- INFORMACI6N DE SALIDA ZANDO UNA CONE×I6N DE 3 CABLES -4LADVERTENCIA- EN CANAD/_ Y LOS ESTADOS UNIDOS, EL DIAMETRO SI ASi LO REQUIRIERAN LOS CODIGOS TORNILLO CINTA DE CONEXION LOCALES, INSTALE UNA CONEXION VERDE TIERRA DE CONDUCTO DE SALIDA REQUERIDO...
  • Page 11 Instrucciones de instalaci6n SALIDA TRASERA ESTANDAR SELLADODE JUNTAS • Todaslasjuntas deben estar bien selladaspara evitar p@didas. (Ventilaci6n a nivel del suelo) Elextremo macho de cada secci6nde conducto debe apuntar en direcci6n opuesta ala secadora. Para una instalaci6n en linea recta, conecte •...
  • Page 12 Instrucciones de instalaci6n []C6MO • Para muchas aplicaciones, se recomienda enf6ticamente NIVELAR Y ESTABILIZAR SU la instalaci6n de codos en la secadora yen la pared SECADORA (ver ilustraciones de abajo). Los codos permiten que la Coloque la secadora en posici6n vertical cerca de la secadora se ubique cerca de la pared sin torcer o aplastar ubicaci6n definitiva y ajuste las cuatro patas de nivelaci6n, el conducto de transici6n, Io que potencia al mOximo el...
  • Page 13 Instrucciones de instalaci6n UBICACI6N DE LA LENGOETA INSTALACION EN BAI_JOS O DORMITORIOS • Esta secadora DEBEtener una ventilaci6n al exterior. Ver la INFORMACIONSOBRESALIDA secciones 3 y 4. • La instalaci6n debe cumplir con c6digos locales o, si no existieran, con el CODIGO ELt_CTRICO NACIONAL, ANSI/ NFPAN°...
  • Page 14 Instrucciones de instalaci6n C6MO C6MO AGREGAR CODOS Y CONDUCTOS AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABI N ETE (SALI DAS DE SALIDA HACIA LA IZQUIERDA O DERE- CHA DEL GABINETE POR LOS LADOS Y LA PARTE INFERIOR) •...