Installation
Instructions
[] ELECTRICAL CONNECTION
INFORMATION
I G
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, AND PERSONAL
INJURY:
"DO NOT USE AN EXTENSION CORD
OR AN ADAPTER PLUG WITH THIS
APPLIANCE.
The dryer must be electrically grounded in accordance
with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA70 or Canadian
Electrical Code, CSAC22.1.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to a properly grounded branch circuit, pro -
tected bg a 15- or 20-amp circuit breaker or time delay
fuse. If electrical supply provided does not meet the
above specifications,
it is recommended that a licensed
electrician install an approved outlet.
AWAR
I G
Electrical
Shock
Hazard
Plug into a grounded
3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension
cord.
Failure to do so can result in death, fire, or electrical
shock.
I G
THIS DRYER IS EQUIPPED WITH A
THREE-PRONG (GROUNDING) PLUG FOR
YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE. DO NOT
CUT OR REMOVE THE GROUNDING
PRONG FROM THIS PLUG.
ELECTRICAL CONNECTION INFORMATION
ENSURE
PROPER
GROUND
EXISTS
BEFORE
USE
IF LOCAL CODES PERMIT,
AN EXTERNALGROUND
WIRE (NOT PROVIDED),
WHICH MEETS
LOCAL CODES, MAY BE
ADDED BY ATTACHINGTO
THE GREEN GROUND
SCREW ON THE REAROF
THE DRYER,AND TO A
GROUNDED METALCOLD
WATER PIPE OR OTHER
ESTABLISHEDGROUND.
CABLE OUTLET
[]
EXHAUST INFORMATION
AWAR
I G
IN CANADA
AND THE UNITED
STATES, THE
REQUIRED
EXHAUST
DUCT DIAMETER
IS 4 in
(102ram).
DO NOT USE DUCT LONGER THAN
SPECIFIED
IN THE EXHAUST
LENGTH TABLE.
Using exhaust longer than specified length will:
, Increase the drying times and the energy cost.
, Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The correct
exhaust
installation
is YOUR
RESPONSIBILITY. Problems
due to incorrect
installation
are not covered
bg the warranty.
Remove and discard existing plastic or metal foil
transition
duct and replace with UL listed
transition
duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall
cap), and all conditions noted below. The maximum duct
length for rigid metal duct is shown in the table below.