[Channel No/Alarm In No]
• Set the channel/alarm number to monitor.
[Source Preset]
• Sets the initial PTZ preset location.
[Target Preset]
• Sets the target PTZ preset location.
[Duration Time]
• 10~300 SEC : Set the delay time at the target preset position before returning to the source preset.
• OFF : Automatically returns to the initial position.

4.3.2 Alarm In Setting

• Configure Alarm In type Normally Open and Normally Close setting and beep option.
[Alarm In]
• Select the Alarm In number for configuration.
[Signal Type]
• The Alarm In type can be set to "Normally Open", or "Normally Close".
• Normally Closed type = If the door/object with the Alarm In installed is not closed, the Alarm In will trigger.
• Normally Open Type = If the door/object with the Alarm In installed is not opened, the Alarm In will trigger
[Beep]
• When Alarm In are triggered, the system will produce "Beep" alarm sound through its internal speakers.
Select "ON" to enable alarm, and select "OFF" to disable it.