IKEA IUD9750WS4 Installation Instructions Manual
IKEA IUD9750WS4 Installation Instructions Manual

IKEA IUD9750WS4 Installation Instructions Manual

Undercounter dishwasher
Hide thumbs Also See for IUD9750WS4:

Advertisement

Available languages

Available languages

|KEA
®
INSTALLATION INSTRUCTIONS
UNDERCOUNTERDISHWASHER
INSTRUCTIONSD'INSTALLATION
LAVE-VAISSELLE SOUS PLAN DE TRAVAIL
Table of Contents ..............................................................
2
Table des matieres ..........................................................
25
W10329312A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IUD9750WS4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IKEA IUD9750WS4

  • Page 1 |KEA ® INSTALLATION INSTRUCTIONS UNDERCOUNTERDISHWASHER INSTRUCTIONSD'INSTALLATION LAVE-VAISSELLE SOUS PLAN DE TRAVAIL Table of Contents .............. Table des matieres ............W10329312A...
  • Page 2: Table Of Contents

    TABLEOF CONTENTS DISHWASHER SAFETY ................INSTALLATION REQUIREMENTS (CONT.) Determine Cabinet Opening ..............INSTALLATION REQUIREMENTS ............. Tools and Parts ..................Install Door Handle (on some models) ........... Custom Panel Dimensions ..............Location Requirements ................Drain Requirements .................. Install Custom Panel (For model IUD9500W) ......... Choose Attachment Option ..............
  • Page 3: Installation Requirements

    Parts needed: INSTALLATION %, Compr x ¾,! hose fitting F0i part or kit.see local REQUIREMENTS retai!er or Call Whirlpool Parts: %800,442-9991. Part Number w10273460 Gather the recommended tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
  • Page 4: Location Requirements

    Check l ocation w here d ishwasher willbeinstalled. The location must p rovide: • easy access towater, electricity and drain. @rounded electrical supply r equired. convenient access forloading a nd unloading dishes. Donotrundrain lines, water l ines orelectrical wiring where t hey Corner locations require a 2"(5.1 cm) m inimum c learance caninterfere withorcontact dishwasher motor orlegs.
  • Page 5 *insulation be compressed. (not used on a I models) Check that all surfaces have no protrusions that wpuld prohibit dishwasher installation. NOTE: Shaded areas of cabinet walls show where utility connections may be installed. *Measured from the lowest point on the ..underside of countertop.
  • Page 6: Drain Requirements

    A new drain hose is supplied with your dishwasher. If drain Be sure that the electrical connection and wire size are adequate hose is not long enough, use a new drain hose with a and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition and all local codes and ordinances.
  • Page 7: Installationinstructions

    INSTALLATIONINSTRUCTIONS Water line Electrical Shock Hazard Disconnect electrical power at the fuse box or circuit breaker box before installing dishwasher. Failure to do so can result in death or electrical shock. If the water line and the cable extend to the locations shown, proceed to the "Install Drain Hose"...
  • Page 8: Prepare And Route Water Line

    Direct Wi re-Ro ute cable"} Wood cabinet: Sand thehole until s mooth. Route cable from power supply through cabinet hole (cable must extend to the right front side of cabinet opening). Tape cable to Metal cabinet: Cover hole withgrommet included withpower the floor in area shown.
  • Page 9: Install Drain Hose

    Slowly route water supply line through hole in cabinet. (If you are Connect the 3/8"compression fitting to the water supply line prior using copper tubing, it will bend and kink easily, so be gentle.) It to installing the unit into the cabinet opening. Attach such that the should be far enough into the cabinet opening to connect it to the dishwasher inlet on the front left side of the dishwasher.
  • Page 10 1. Connect black end of drain hose to waste tee and cut if needed. NOTE: Do not cut ribbed section. Connect drainhose towaste teeor waste disposer Using0heofthefollowing 0ptions: Attach black end of drain hose to iiii ; Option A ;Waste disposer #noairgap waste tee with a large silver drain hose clamp (provided).
  • Page 11: Install Moisture Barrier (Under A Wood Countertop)

    Option D, No waste disposer - with air gap Tip Over Hazard Do not use dishwasher until completely installed. Do not push down on open door. Doing so can result in serious injury or cuts. !; ! ;_ __; i i;A¸! ii!!i;;; ;;ii; ¸ ; i ; ; i¸_:;I ; i _!;;;!;ii_i i;;;, Connect black end of drain hose to air gap and cut if needed.
  • Page 12: Make Power Supply Cord Connection

    NOTE: If using Option B, proceed to "Determine Cabinet Opening," to continue with the installation of your dishwasher. Mcsk® Pow®t; S_ _s'sv Co_ Co_%s®ct o_/_ .._,_ t _,;_'..Option A, Power Supply Cord: Using a 1/4"hex head socket, nut driver or Phillips screwdriver, remove terminal box cover.
  • Page 13 16-gauge dishwasher wiring. supply cord kit). Electrical Shock Hazard If needed, see website for animated representation of this step. Visit www.ikea.com under FAQ tab. Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box.
  • Page 14: Installation Requirements (Cont.) Determine Cabinet Opening

    Built-up floors: If the kitchen floor is higher than the cabinet opening's floor - for example, the kitchen floor tile does not Measure height of cabinet opening from underside of countertop extend into the cabinet opening - add shims as needed in the area to floor where dishwasher will be installed (you will need to shown to bring the dishwasher up to 34"...
  • Page 15: Custom Panel Dimensions

    IMPORTANT: You need to know which control panel is on your dishwasher before your order your custom door panel. NOTE: The handle for the custom panel is not included. IMPORTANT: If the handle is attached from the back of the hw;i=1 custom panel, the screw holes should be countersunk for the...
  • Page 16 __J Custom panel dimensions-- Dishwashers with control panel on the top 3 screws per side Attach outer panel to back of customer-supplied custom panel outer r with the four #10-16 x 3/8"hex head screws supplied in the literature package. Attach the handle. The handle should be Gently set outer panel aside.
  • Page 17: Choose Attachment Option

    edges )rilithrough these holes Using a pair of pliers, bend the tab down to secure the bracket in place. Repeat this step for the other side. Customer-supplied NOTE: Do not attach the dishwasher. This will be done later. panel Option 2, Dishwasher side attachment: Install the two #8-18 x 13/8"screws from the literature package in NOTE: Remove the brackets from the parts package.
  • Page 18: Move Dishwasher Close To Cabinet Opening

    © kcy C ctb ne$ Excessive Weight Hazard Use two or more people to move and install dishwasher. Failure to do so can result in back or other injury. Check that water line is on the left side of opening and drain hose is near the center of the cabinet opentng.
  • Page 19 Check that leveling legs are firmly against the floor. Close and latch the door, and place level against the front panel. Check that dishwasher is centered from front to back in the opening. If When door is unlatched and door opens by itself, move the needed, adjust leveling leg until dishwasher is plumb.
  • Page 20: Connect To Water Supply

    Place paper towel under 90 ° elbow fitting. Turn on water supply and check for leaks. If leak occurs, repeat previous step. If needed, see website for animated representation of this step. Visit www.ikea.com/watersupply under FAQ tab. NOTE: Do not use Teflon ®ttape with compression fittings.
  • Page 21: Make Direct Wire Electrical Connection

    After hose is connected, remove towel. If needed, see website for animated representation of this step. Visit www.ikea.com/drain under FAQ tab. C@' necton NOTE: If the power supply cord was connected earlier, proceed to "Secure Dishwasher in Cabinet Opening" section.
  • Page 22: Secure Dishwasher In Cabinet Opening

    D/sB sBe/" Cc bne Open/sg If needed, see website for animated representation of this step. Visit www.ikea.com/electrical under FAQ tab. Check that dishwasher is still level front-to-back and side-to-side in cabinet opening. Tighten strain relief screws to secure cable. Open dishwasher door, remove lower dish rack, and place towel over pump assembly and lower spray arm of dishwasher.
  • Page 23: Complete Installation

    If it does, adjust leveling legs. If needed, see website for animated representation of this step. Visit www.ikea.com/anchoring under FAQ tab. Open door and check that space between dishwasher cabinet opening and tub is equal on both sides. If spacing is not equal, loosen bracket screws secured and shift tub.
  • Page 24: Check Operation

    Reconnect Power • Read the Dishwasher User Instructions that came with your dishwasher. Check that all parts have been installed and no steps were skipped. Check that you have all tools used. Start dishwasher and allow it to complete the shortest wash cycle.
  • Page 25 TABLEDESMATIERES SI_CURITI_ DU LAVE-VAISSELLE ............INSTRUCTIONS D'INSTALLATION (CONT.) Evaluation de I'ouverture d'encastrement du placard ......36 EXIGENCES D'INSTALLATION ..............Installation de la poign_e de porte (sur certains modeles) ....37 Outillage et pieces .................. Dimensions du panneau personnalis_ ........... Exigences d'emplacement ..............
  • Page 26 Autres pibces pouvant _tre n_cessaires : EXIGENCES D'INSTALLATION Bddes & Visde ..g p®ces Rassembler les outils et composants necessaires avant d'entreprendre I'installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous. Toutes les installations REMARQUES Outillage n_cessaire : •...
  • Page 27 Un ensemble de panneau lateral est disponible chez votre plancher horizontal et plat. (S'il y a un ecart de niveau sur marchand pour I'installation du lave-vaisselle a I'extremit6 d'une le plancher entre I'avant et I'arriere de I'emplacement rangee de placards. d'installation, il pourrait _tre necessaire d'utiliser des cales pour etablir I'aplomb de I'appareil).
  • Page 28 Un tuyau d'@vacuation neuf est fourni avec le lave-vaisselle. Si S'assurer que le raccordement electrique et la taille des ce tuyau n'est pas suffisamment long, utiliser un tuyau conducteurs sont adequats et conformes au code national de d'evacuation neuf de Iongueur maximale de 12' (3,7 m) (piece I'electricite, ANSI/NFPA 70 - derniere edition, et &...
  • Page 29 INSTRUCTIONS pck/s_ss _-,-- _o:s@%s e D'INSTALLATION Risque de choc _lectrique Interrompre I'alimentation _lectrique avant d'instaiier le lave=vaisseile (au niveau du tableau de distribution = fusible ou disjoncteur) Le non=respect de cette instruction peut causer Si la canalisation d'eau et le c&ble depassent des emplacements un d_c_s ou un choc _lectrique.
  • Page 30 Acheminer le c&ble de la source d'alimentation electrique & travers le trou dans le placard (le c&ble doit depasser par le c6te Placard de bois : Poncer le trou jusqu'& obtenir une surface lisse. avant droit de I'ouverture d'encastrement du placard). Placard metallique : Couvrir le trou avec I'ceillet fourni avec la Fixer le c&ble au plancher avec du ruban adhesif dans la zone indiquee.
  • Page 31 Acheminement de la canalisation 6TRacco;der le;acc dcoud de90 ° d'alimentation en eau a la canalisation d'alimentation en eau[ Acheminer lentement la canalisation d'alimentation en eau & travers le trou du placard. (On doit travailler prudemment si I'on Raccorder le raccord de compression de 3/8"& la canalisation utilise une canalisation de cuivre : celle-ci est malleable et se d'alimentation en eau avant d'installer I'appareil dans I'ouverture...
  • Page 32 A I'aide d'un marteau et d'un tournevis, enfoncer le bouchon 2 IAcheminement du tuyau d'evacuation ..d'obturation dans le broyeur dechets. °'°v°cuati° Retirer le bouchon d'obturation & I'aide d'une pince & pointe biseautee. Fixer le tuyau d'evacuation sur le Inserer le tuyau d'evacuation tel qu'indiqu6 & travers le trou dans raccord de broyeur &dechets &...
  • Page 33 OptionC- broyeur & d_chets - avec brise-siphon Option D - pas de broyeur & d_chets - avec brise-siphon Tuyau d'evacuation Siphon Raccorder I'extremit6 noire du tuyau A I'aide d'un marteau et d'un d'evacuation au dispositif de brise- tournevis, enfoncer le bouchon siphon et couper si necessaire.
  • Page 34 Risque de basculement hie pas utiliser le lave=vaisselle jusqu'_ ce qu'il soit compl_tement installS. hie pas appuyer sur la porte ouverte. Le non=respect de ces instructions peut causer des blessures graves ou des coupures. A I'aide d'une cle a douille, un tourne-ecrou ou un tournevis Phillips de 1/4",6ter le couvercle du boiler de connexion.
  • Page 35 Option A, cordon d'alimentation Risque de choc _lectrique Relier le lave=vaisselle _ la terre d'une m_thode _lectrique. Brancher le fil reli_ & la terre au connecteur vert reli_ la terre darts la boite de la borne. Ne pas utiliser un c&ble de rallonge. Le non=respect de ces instructions peut causer un d_c_s, un incendie ou un choc _lectrique.
  • Page 36 CSA) (fournis avec I'ensemble de cordon d'alimentation). du pacad Mesure de I'ouverture d'encastrement du placar la terre Au besoin, visiter le site Web pour une representation video de cette etape. Visiter www.ikea.com sous I'onglet FAQ. Cordon d'alimentation _lectrique Fixation du cordon sur le serre-c_ble...
  • Page 37 D ne_s,sos du, pen_secs,, ..s:;e_'so_ se, .. .,.. _/s,(s IMPORTANT : II faut savoir de quel tableau de commande est dote le lave-vaisselle avant de commander le panneau de porte personnalise. Dimensions pour lave-vaisselle avec tableau de commande sur panneau personnalis_ superieur .31..,...
  • Page 38 I Dimensions pour lave-vaisselle avec tableau de commande panneau personnalis6 sup rieur REMARQUE : La poignee destinee au panneau personnalise n'est pas comprise. IMPORTANT : Si la poignee est fixee & I'arriere du panneau personnalise, les trous de vis doivent _tre fraises de fa£_on& ce que les t_tes de vis soient en affleurement avec le panneau.
  • Page 39 Panneau achet6 par le client Installer le panneau externe sur I'arriere du panneau personnalise Installer les deux vis n°8-18 x 13/8",provenant du sachet de fourni par le client & I'aide des quatre vis &tete hexagonales documentation, dans les coins superieurs du panneau interne. n°10-16 x 3/8"fournies avec le sachet de documentation.
  • Page 40 A I'aide d'une pince, replier la languette vers le bas pour fixer la bride. R6peter cette etape pour I'autre c6t& Enfoncer la bride dans la fente sur le c6te du lave-vaisselle et REMARQUE • Ne pas fixer le lave-vaisselle. Ceci sera fait replier la languette vers le c6te du lave-vaisselle afin de maintenir ulterieurement.
  • Page 41 Alors quune autre personne retient I'appareil pour I'emp_cher de basculer, ouvrir et refermer la porte plusieurs fois. Si la porte se ferme ou s'ouvre sous I'effet de son propre poids, il sera necessaire d'ajuster la tension du ressort de la porte. IMPORTANT : Verifier que le c&blage est bien installe.
  • Page 42 La porte s'ouvre et retombe ........Augmentation de la tension du ressort Aligner I'avant du panneau de porte du lave-vaisselle avec les portes des placards. II faudra peut-_tre ajuster I'alignement de celui-ci pour qu'il soit en affleurement avec les placards. Lorsque la porte est deverrouill6e, si elle s'ouvre d'elle-m_me, deplacer le tendeur vers un trou numerot6 superieur et replacer la vis.
  • Page 43 Ouvrir I'alimentation en eau et inspecter pour identifier toute fuite. Si une fuite se produit, rep6ter I'etape pr6cedente. Au besoin, visiter le site Web pour une representation video de cette etape. Visiter www.ikea.com/watersupply sous I'onglet Placer le niveau contre la partie superieure de I'ouverture avant de FAQ.
  • Page 44 (non fournis) con_;us pour le raccordement du c&blage du domicile au c&blage de calibre 16 du lave-vaisselle. Une fois le tuyau raccorde, 6ter la serviette. Au besoin, visiter le site Web pour une representation video de cette etape. Visiter www.ikea.com/drain sous I'onglet FAQ.
  • Page 45 ..Au besoin, visiter le site Web pour une representation video de Risque de choc _lectrique cette etape. Visiter www.ikea.com/electrical sous I'onglet FAQ. Relier le lave=vaisselle & la terre d'une m_thode _lectrique. Brancher le fil reli_ _ la terre au connecteur vert reli_ la terre darts la boite de la borne.
  • Page 46 Localiser les brides sur le dessus du lave-vaisselle et fixer celui-ci au plan de travail a I'aide de deux vis Phillips n°l 0 x 1/2"(fournies). x(s;! ol ds,,,s ss® ® dcs ss Le lave-vaisselle doit etre immobilise pour I'empecher de basculer Iors de I'ouverture de la porte.
  • Page 47 Retirer la serviette du lave-vaisselle. Reinstaller le panier vaisselle inferieur. Au besoin, visiter le site Web pour une representation video de cette etape. Visiter www.ikea.com/anchoring sous I'onglet FAQ. Ach®ve c4 on Risque de choc _lectrique Brancher sur une prise & 3 aiv_oles reli_e &...
  • Page 48 8i aucune de ces verifications ne resout le probleme, composer le 1-866-664-2449. W10329312A @2011. 4/11 All rights reserved. @ IKEA is a registered trademark of Inter-lkea Systems B.V. Printed in U.S.A. Tous droits reserves. @ IKEA est une marque deposee de Inter-lkea Systems B.V. Imprime aux E.-U.

This manual is also suitable for:

Iud9500wx4