Gas Requirements - Amana LED20AW-PLED20AW Installation Instructions Manual

Home laundry automatic dryers (electric and gas models)
Table of Contents

Advertisement

Gas Requirements...,
(Gas Dryers)
NOTE: The gas service
to a gas
dryer must conform with the local
codes and ordinances,
or in the
absence of local codes and
ordinances,
with the latest edition
of the National
Fuel Gas Code
ANSI Z223.1/NFPA
54 or the
CAN/CGA-B149,
National
Gas
_[nstallation
Code.
Natural Gas service must be
supplied
at 6.5 + 1.5 inch water
column pressure.
17or proper operatio n at altitudes
above 2,500 feet (760 m) the natural
gas valve spud orifice size must be
reduced to ensure complete
combustion.
See table at right.
L.P. Gas service must be supplied at
10 + 1.5 inch water column
pressure.
NOTE:
DO NOT connect the
dryer to L.P. Gas Service
without
converting
the gas valve. An
LPK1 Sales Accessory
(L.P. Gas
Conversion
Kit 649P3)
must be
installed.)
NOTE:
The dryer and its
appliance
main gas valve must be
disconnected
from the gas supply
piping
system
during any
pressure
testing of that system at
lest pressures
in excess of 1/2 psi
(3.45 kPa). (See illustration
on
page 10.)
The dryer must be isolated from the
gas supply piping system by closing
the equipment
shut-off valve during
any pressure testing of the gas
supply piping system at test
pressures
equal to or less than
[/2 psi (3.45 kPa)
NOTE:
When connecting
to a gas
line, an equipment
shutoff
valve
must be installed
within 6' (1.8 m)
of the dryer. An 1/8" (3.1 ram)
N.P.T. pipe plug must be installed
as shown. See illustration.
WARNING
To reduce the risk of gas leaks, fire or explosion:
• The dryer must be connected
to the type of gas as shown
on
nameplate
located
in the door recess.
• Use a new flexible
metal connector.
• Use pipe joint compound
insoluble
in LP Gas on all pipe
threads.
• Purge air and sediment
from
gas supply line before
connecting
it to the dryer. Before tightening
the connection,
purge remaining
air from gas line to dryer until odor of gas is
detected.
This step is required
to prevent
gas valve
contamination.
• Do not use an open flame to check for gas leaks. Use a non-
corrosive
leak detection
fluid.
Wl14
Altitude
Orifice
Size
Part
m
#
Inches
mm
Number
3000
915
43
0.0890
2.26
503778
6000
!830
44
0.0860
2.18
58719
8000
2440
45
0.0820
2.08
503779
9000
2740
46
0.0810
2.06
503780
10000
3050
47
0.0785
1.99
503781
NEW
METAL
\
FLEXIBLE
coN.EChO.\
USE ONLY
_,,_
_.
IF ALLOWED
_"
_
BY LOCAL
CODES
,_
(Use
Design A.G.A.
l_
Certified
Connector)
3/8" (9.5 ram) NPT /
_
GAS
CONNECTION
BLACK IRON PIPE
Shorter than 20' (6.1 m) - use 3/8" pipe ____-
Longer than 20' (6.1 m) - use 1_2" pipe
1/8" (3.1 mm) NPT
PIPE
PLUG
._
(For checking
inlet gas; pressure)
QUIPMENT
1"-11
SHUT-OFF
.j]
_
_
VALVE
_
_._ 2 _)_ -_
Installed
within
,_
6' (1.8 m) of dryer
503953
15