Installation Instructions
for Stacked Dryers
Inside ......................................
........................................................................
3
Before You Start ................................................................
4
the Dryer ............................................................
5
Checklist ..............................................................
Back Cover
Para bajar una copia de estas instrucciones
en espafiol, visite www.speedqueen.com.
Keep these instructions
for future reference.
(If this machine
changes ownership,
this manual must accompany
machine.)
Date Purchased
Model Number
Serial Number
www.speedqueen.com
Part No. 512063R3
June 2007

Advertisement

loading
Need help?

Need help?

Do you have a question about the CTSA9AWN and is the answer not in the manual?

Questions and answers

Summary of Contents for Alliance Laundry Systems CTSA9AWN

  • Page 1 Installation Instructions for Stacked Dryers Inside ........Dimensions ................ Before You Start ..............Installing the Dryer ............Installer Checklist .............. Back Cover Para bajar una copia de estas instrucciones en espafiol, visite www.speedqueen.com. Keep these instructions for future reference. (If this machine changes ownership, this manual must accompany machine.)
  • Page 2 No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 3: Dimensions

    "15.44 in. (71.1 cm) (39.2 cm) 26.9 in. 0.4 in. (1.1 cm) (68.3 cm) GAS DRYERS DRY2213N *With leveling legs turned into base. 3/8 in. NPT Gas Connection 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 4: Before You Start

    Wrench Duct Tape Teflon Tape (Gas Models) Figure 1 WARNING Any disassembly requiring the use of tools must be performed by a suitably qualified service person. W299 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 5: Installing The Dryer

    Exhaust duct clearance to combustible material 2 in. (5.1 cm) installations, locate top venting **NOTE: For new of wall vent 42 inches (106.7 above floor to make easier to connect. Figure 2 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 6 Use duct tape or pop-rivets on all duct joints. • Ductwork that runs through unheated areas must be insulated to help reduce condensation and lint build-up on pipe walls. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 7 (7.6 m) 17 feet (5.2 m) 20 feet (6.1 m) 15 feet (4.5 m) NOTE: Deduct 6 feet (1.8 m) for each additional elbow. Table 1 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 8 (915 m) the natural gas valve spud orifice size must be Use 3/8 in. (9.5 mm) pipe reduced to ensure complete combustion. Refer to 3/8 in. NPT Gas Connection Table 2. Figure 5 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 9 It is the customer's responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer. W521 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 10 3. Use a strain relief and insert end of power cord 1. Disconnect power to dryer. through power supply hole. 2. Remove access cover from rear of dryer. D6961 D6951 Figure 8 Figure 7 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 11 8. Reinstall access cover and screw. D6951 Figure 11 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 12 10. Reinstall access cover and screw. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 13 120 Volts AC (alternating current) 15 Amps. Refer to Figure ! 7 to determine correct polarity of the wall receptacle. Connect to 30 Amp circuit. D2751 Figure 16 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 14 To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source, W037 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512063...
  • Page 15 Adjust the air shutter as follows: D7021 Air Shutter Lockscrew Air Shutter Appliance Main Gas Valve 1/8 in. (3.1 mm) Pipe Plug (For checking manifold pressure) Figure 18 512063 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 16: Installer Checklist

    Installer Checklist Fast Track for Installing the Unit (Refer to the manual for more detailed information) • Position and • Wipe Out Inside of Dryer. ® LEVEL ® D2551 Level the Dryer. D2561 CHECK DRY2058N CHECK D2591 • Connect Dryer Exhaust System.