Malloca H214.6 User Manual

Built -in hood

Advertisement

H214.6/7/9 SS
BUILT -IN HOOD
USER'S MANUAL
For original parts & reliable service:
INSTRUCTIONS FOR INSTALLATION
BACH HOP KITCHEN WARE COMPANY
AND USE
LIMITED
279 Nguyen Van Troi Street,
Phu Nhuan District, Ho Chi Minh City, Vietnam.
Tel : + 84 8 8625726
Fax : + 84 8 8625727

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H214.6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Malloca H214.6

  • Page 1 H214.6/7/9 SS BUILT -IN HOOD USER’S MANUAL For original parts & reliable service: INSTRUCTIONS FOR INSTALLATION BACH HOP KITCHEN WARE COMPANY AND USE LIMITED 279 Nguyen Van Troi Street, Phu Nhuan District, Ho Chi Minh City, Vietnam. Tel : + 84 8 8625726...
  • Page 2 Troubleshooting Table of Contents From the Manufacturer • Symptoms Possible Cause Action Specifications • Check that the plug is SAFETY : Read this first ! 4, 5 • connected. Does not function No electrical supply Description of Parts 5, 6 •...
  • Page 3: From The Manufacturer

    Cleaning & Maintenance From the Manufacturer (Continued) Activated charcoal filter • This appliance and it’s packaging are produced by processes that To install the charcoal filter, the motor anchorage is made to coincide with the minimize waste and respect the environment. anchor points of the activated charcoal filter and turn in clockwise.
  • Page 4 SAFETY : Read this First ! Cleaning & Maintenance • Do not connect the appliance if there are obvious signs of transportation damage. Before carrying out any cleaning or maintenance activities, ensure that the • Read this user manual thoroughly before attempting to use this appliance. appliances is disconnected from the mains.
  • Page 5: Description Of Parts

    Installation SAFETY : Read this First ! (Continued) • There shall be adequate ventilation of the room when the range hood is To fix the extractor to the kitchen unit. used at the same time as appliances burning gas or other fuels (not The lower part of the extractor must be located at a minimum height of 60cm applicable to appliances that only discharge the air back into the room);...
  • Page 6: Instructions For Use

    F Possibility of incorporating activated charcoal filter. Light On/Off Button (i) G-H Anti return tabs to be located in the outlet mouth, locating ends in the On/Off switch for the light. Push the button in to turn the light ON, holes provided.

This manual is also suitable for: