2=
Connect the flexible stainless steel connector to the pressure
regulator using a 1/2"male pipe thread adapter.
A combination
of pipe fittings must be used to connect the
cooktop to the existing gas line. Shown following is a typical
connection.
Your connection may be different, according to
the supply line type, size and location.
3. Use a 1%4' combination
wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
A. Gas pressure regulator
B. Regulator
- Must be installed with arrow
pointing
up to cooktop bottom
C. Adapter - Must have ½" male pipe thread
D. CSA approved flexible stainless steel gas
supply line
3. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop burner base and in a
position where you can reach the regulator cap.
IMPORTANT: All connections
must be wrench-tightened.
Do
not make connections
to the gas regulator too tight. Making
the connections
too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn on the pipe
when tightening fittings.
Use only pipe-joint compound made for use with Natural and
LP gas. Do not use TEFLON ®tape.
You will need to determine the fittings required depending on
your installation.
4. Place cooktop into the countertop
cutout.
NOTE: Check that the front edge of the cooktop is parallel to
the front edge of the countertop.
If repositioning
is needed,
lift entire cooktop up from cutout to avoid scratching the
countertop.
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
C;
H.
E
P
G
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter - Must have V2"
male pipe thread
D. Flexible connector
E. Adapter
F Use pipe-joint
compound.
G. V2" or 3/4"gas pipe
H. Manual gas shutoff valve
Complete
Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
2. Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove surface burner caps and grates from parts package.
Place burner caps on burner bases. Place burner grates over
burners and caps.
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
4. Plug into a grounded 3 prong outlet.
5. Check the operation of the surface burners. See "Check
Operation of Cooktop Burners" section in the "Electronic
Ignition System" section.
6. If your model has a griddle, see the "Install Griddle" section.