LOW FLAME
ADJUSTMENT
(See illustration "D")
This appliance is shipped from the factory with low and
medium flame settings adjusted for use with natural gas.
If further adjustment is necessary, or to readjust for use
with LP, proceed as follows:
1. Light burner and set control knob for low flame•
2. Remove control knob from valve stem.
CAUTION:
NEVER USE A METAL BLADE TO PRY
KNOB OFF. IF KNOB CANNOT BE EASILY
REMOVED, TUCK FOLDS OF A CLOTH
DISHTOWEL
UNDER THE KNOB AND PULL THE
TOWEL UPWARD WITH STEADY, EVEN
PRESSURE.
3• Insert a slender, thin-blade screwdriver into the recess
at center of valve stem and engage blade with slot in
adjusting screw.
4. Turn center stem adjusting screw to set flame size.
•.. clockwise to reduce.
•.. counterclockwise
to increase.
5• Replace control knob when adjustment is completed.
Proper adjustment will produce a stable, steady blue
flame of minimum size. The final adjustment should be
checked by turning knob from high to low several times
without extinguishing the flame.
This adjustment, at low setting, will automatically
provide
the proper flame size at medium setting.