Advantech RS-200-RT User Manual
Advantech RS-200-RT User Manual

Advantech RS-200-RT User Manual

2u server

Advertisement

Quick Links

User's Manual
RS-200-RT
2U Server

Advertisement

Table of Contents
loading

Summary of Contents for Advantech RS-200-RT

  • Page 1 User’s Manual RS-200-RT 2U Server...
  • Page 2 Copyright Notice This document is copyrighted, 2001, by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied,...
  • Page 3 All other product names or trademarks are properties of their respective owners. CE Notification RS-200-RT-R3-R3, RS-200-RT-S3-S6, RS-200-RT-R3-S6 and RS-200-RT-TB, developed by Advantech Co., Ltd., has passed the CE test for environment specifications when shielded cables are used for external wiring. We recommend the use of shielded cables.
  • Page 4 Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight.
  • Page 5 1. Collect all the information about the problem encountered. For example, CPU speed, Advantech products used, other hardware and software used, etc. Note anything abnormal and list any on-screen messages you get when the problem occurs. 2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available.
  • Page 6 Holder for full size Add-on Card 2 Screw sinks for holder Technical Support and Sales Assistance If you have any technical questions about the RS-200-RT series products, please visit our support website at http://www.advantech.com.tw/support For more information about Advantech products and sales information, please visit: http://www.advantech.com.
  • Page 7: Table Of Contents

    2.8 Installing LAN module -------------------------- 47 2.9 Installing Zero Channel HW RAID Module -- 48 2.10 Adding Disk drives ----------------------------- 49 2.11 Installing Rail Slider --------------------------- 51 Chapter 3 BIOS Setup ------------------------------ 53 3.1 Function Keys ------------------------------------ 53 RS-200-RT User’s Manual...
  • Page 8 Appendix B RAID Card Approval List --------- 82 Appendix C Accessory Order Information ----- 82 Appendix D Safety Instructions ------------------ 83 D.1 English -------------------------------------------- 83 D.2 German- Wichtige Sicherheishinweise ----- 85 Appendix E GEM318 Driver Installation ----- 87 RS-200-RT User’s Manual...
  • Page 9 RS-200-RT User’s Manual...
  • Page 10: Chapter 1 Introduction

    (Tualatin) Processors, and provides flexibility and high performance at the same time. The RS-200-RT series of thin servers is well placed to compete at the forefront in this fast-paced product sector. Thin servers are rapidly becoming the platform of choice for Internet, VOD (Video on Demand), industrial and telecom-focused applications.
  • Page 11 SCSI storage devices, high-speed network interfaces and specially designed fault detection and management features. These all add up to a hardware solution that provides the kind of high availability required by demanding applications. RS-200-RT User’s Manual...
  • Page 12: Specifications

    32bit/33MHz PCI slot on two riser card 1 x RS-232 port, 2 x USB ports, 1 x VGA port, 2 x PS/2 ports for keyboard and mouse port, 3 x LAN ports (one option), 1 x parallel port RS-200-RT User’s Manual...
  • Page 13 SNMP MIB-base software for system remote monitoring. Weight 14.4kg (31.7lb) Paint Color Black 4U 2X, Fabric Texture Operating Temp. 0 ~40℃ (32 ~104℉) Storage Temp. -20 ~70℃ (-4 ~158℉) Operating Hum. 5~95% @ 40℃ Storage Humidity 5~95% RS-200-RT User’s Manual...
  • Page 14 Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI Linux, Free BSD 4.x, Win 2K/NT 4.0, Solaris 8.x RS-200-RT User’s Manual...
  • Page 15 32bit/33MHz PCI slot on two riser cards 1 x RS-232 port, 2 x USB ports, 1 x VGA port, 2 x PS/2 ports for keyboard and mouse port, 3 x LAN ports (one option), 1 x SCSI port, 1 x parallel port RS-200-RT User’s Manual...
  • Page 16 SNMP MIB-base software for system remote monitoring. Weight 14.4kg (31.7lb) Paint Color Black 4U 2X, Fabric Texture Operating Temp. 0 ~40℃ (32 ~104℉) Storage Temp. -20 ~70℃ (-4 ~158℉) Operating Hum. 5~95% @ 40℃ RS-200-RT User’s Manual...
  • Page 17 Storage Humidity 5~95% Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI Linux, Free BSD 4.x, Win 2K/NT 4.0, Solaris 8.x RS-200-RT User’s Manual...
  • Page 18 32bit/33MHz PCI slot on two riser cards 1 x RS-232 port, 2 x USB ports, 1 x VGA port, 2 x PS/2 ports for keyboard and mouse port, 3 x LAN ports (one option), 1 x SCSI port, parallel port RS-200-RT User’s Manual...
  • Page 19 SNMP MIB-base software for system remote monitoring. Weight 12.9kg (28.4lb) Paint Color Black 4U 2X, Fabric Texture Operating Temp. 0 ~40℃ (32 ~104℉) Storage Temp. -20 ~70℃ (-4 ~158℉) Operating Hum. 5~95% @ 40℃ RS-200-RT User’s Manual...
  • Page 20 Storage Humidity 5~95% Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D Certifications FCC Class A, CE, UL, CUL, BSMI Linux, Free BSD 4.x, Win 2K/NT 4.0, Solaris 8.x RS-200-RT User’s Manual...
  • Page 21 32bit/33MHz PCI slot on two riser cards Sustain 5~10 min power for emergency backup 2 x USB ports, 1 x VGA port, 2 x PS/2 ports for keyboard and mouse port, 3 x LAN ports (one option), 1 x parallel port RS-200-RT User’s Manual...
  • Page 22 Black 4U 2X, Fabric Texture Operating Temp. 0 ~40℃ (32 ~104℉) Storage Temp. -20 ~70℃ (-4 ~158℉) Operating Hum. 5~95% @ 40℃ Storage Humidity 5~95% Dimension 482mm (19”) W x 88mm (3.46”) H x 600mm (23.6”) D RS-200-RT User’s Manual...
  • Page 23 Certifications FCC Class A, CE, UL, CUL, BSMI Win 2K/NT 4.0, Linux RS-200-RT User’s Manual...
  • Page 24: External Connection

    USB device directly to the USB connector. LAN Connectors (8-pin): The serverboard provides three LAN connectors with two status LEDs. One LED indicates whether 100Mbit protocol is active. Another one indicates whether LAN is active or at linking. RS-200-RT User’s Manual...
  • Page 25 Serial Port Connector: The serverboard has one 9-pin male DIN connector for RS-232 port. VGA port Connector (15-pin D-SUB): The port allows user connect it to external Monitor. PS/2 Keyboard Connector: The connector is for a standard PS/2 keyboard only. RS-200-RT User’s Manual...
  • Page 26: Front Panel

    1.3 Front Panel 1.3.1 RS-200-RF-R3-S6 and RS-200-RT-S3-S6 Please use a key in accessory box to unlock the front cover. Front Panel Alarm CD-ROM Power Switch LEDs Mute System Reset HDD1 HDD4 HDD2 HDD5 HDD3 HDD6 System Status Panel Indicator Description...
  • Page 27 1.3.2 RS-200-RT-R3-R3 and RS-200-RT-TB Front Panel CD-ROM/DVD-ROM Power Switch LEDs B-ID1 B-ID2 B-ID3 A-ID1 A-ID2 A-ID3 Note: No power switch for RS-200-RT-TB System Status Panel Indicator Description Voltage Voltage/Redundant Power Failure Temperature Red Overheating Fan Failure LAN 1 Green Active...
  • Page 28: Rear Panel

    1.4 Rear Panel 64-bit PCI slot port 32-bit PCI slot port Power Supply RS-200-RT User’s Manual...
  • Page 29: System Monitoring

    Voltage monitoring and alert: System voltage levels are monitored to ensure stable current flows to critical components. If an alert is triggered, that means a failure status occurs. The system will signal a red light on the front RS-200-RT User’s Manual...
  • Page 30 Alarm LED will still be on unless the problem is solved. The system provides an optional SNMP MIB-base software that allows user to monitor the current health status of this machine via network management software at remote site. RS-200-RT User’s Manual...
  • Page 31 RS-200-RT User’s Manual...
  • Page 32: Chapter 2 System Placement And Installation

    Chapter 2 System Placement and Installation 2.1 System Placement Power Supply Motherboard CD-ROM/ DVD-ROM RS-200-RT User’s Manual...
  • Page 33: Motherboard Placement

    CD-ROM Port Southbridge Power module μP CPU0 socket CPU1 socket FDD port IDE port Power Connector Note: If machine installs one CPU only, please insert it in CPU0 socket. Terminator board should be placed in CPU1 socket. RS-200-RT User’s Manual...
  • Page 34 Gigabit Lan3 Active LED connect J6 pin6 LAN3 LED JP1-Alarm board device sensor setting. Jumper Function Remark PIN 1-2,3-4,5-6,7-8,9-10 Closed RS-200-RT One CPU Note1,3 PIN 3-4,5-6,7-8,9-10 Closed RS-200-RT Two CPU Note1 PIN 1-2,5-6,7-8,9-10 Closed RS-200-RT One CPU Note2,3 PIN 5-6,7-8,9-10 Closed RS-200-RT Two CPU Note2...
  • Page 35 Note2: Case Fan must connect to CN27--FAN(2B0), CN29--FAN(2B2),CN30--FAN(2B3). Note3: One CPU must work on U35, U36 add a CPU terminator board. Note4: CN16---Redundant power fail. Note5: CN31---Thermal sensor . Note6: CN32---Case Open sensor. Note7: CN25---connects to LED board. RS-200-RT User’s Manual...
  • Page 36: Scsi Backplane Placement

    SCA-2 SCSI HDD Connector (ID 5) SCA-2 SCSI HDD Connector (ID 6) SCA-2 SCSI HDD Connector (ID 4) SCA-2 SCSI HDD Connector (ID 2) SCA-2 SCSI HDD Connector (ID 3) CN10 SCA-2 SCSI HDD Connector (ID 1) RS-200-RT User’s Manual...
  • Page 37 SCA-2 SCSI HDD Connector (Ch-B ID 3) SCA-2 SCSI HDD Connector (Ch-A ID 2) CN10 SCA-2 SCSI HDD Connector (Ch-B ID 1) CN11 Power Connector CN12 Channel B, 68-pin SCSI Connector (to Host) CN13 Connector for HDD failure and activity RS-200-RT User’s Manual...
  • Page 38: Installing Cpu

    CPUs, first turn off your system, remove its cover and follow the directions below that come with the CPUs. Always observe static electricity precautions when installing CPUs. The general procedure is: Pull the lever outward RS-200-RT User’s Manual...
  • Page 39 Raise the retaining lever of CPU socket to a position perpendicular to the socket up. Orient the CPU to the socket correctly so that the pins match the receptacles. Insert the CPU in the socket so that the pins fully insert. RS-200-RT User’s Manual...
  • Page 40 CPU terminator is the same as CPU. Warning: Without a fan or heat sink, a CPU will overheat and cause damage to both the CPU and the main board. It is not necessary to install CPU cooler fan for CPU terminator. RS-200-RT User’s Manual...
  • Page 41: Installing Cpu Cooler

    CPU coolers that sit on the top of an installed CPU and clip onto the CPU socket. The general procedure is: Take out the heat-spread glue. Paint the heat-spread glue on the CPU die evenly. RS-200-RT User’s Manual...
  • Page 42 Place the clip to hold the protrusion on another side of CPU socket. Press the spring clip over the protrusion so that it snaps in place. Plug the power connector of CPU cooler fan into power socket (CN17 for CPU0 socket, CN18 for CPU1 socket). RS-200-RT User’s Manual...
  • Page 43 Please use extra caution when installing any type of clamp-style fan, or else damage may occur to the CPU socket, and/or the CPU itself Note: In order to upgrade to support higher speed CPU, manufacture maybe changes to use new CPU cooler fan. RS-200-RT User’s Manual...
  • Page 44: Installing System Memory

    Orient the module so that the edge connector sections correctly match the socket sections. Holding the module to the socket, place it in the socket so that the edge connectors insert slightly in the socket. Make sure they match. RS-200-RT User’s Manual...
  • Page 45 Note: Serverworks III LE chipset can support system memory size up to 4GB, but it depends on OS support. It means if OS only supports system memory up to 2GB, then the system with this OS installed also supports system memory up to 2GB. RS-200-RT User’s Manual...
  • Page 46: Installing Add-On Cards

    The detailed installation procedure is stated as follows: Remove the pre-installed bracket so that add-on card bracket can be inserted. Put down the add-on card. Plug the add-on card horizontally into PCI slot. RS-200-RT User’s Manual...
  • Page 47 Fasten the bracket of the add-on card with screw. RS-200-RT User’s Manual...
  • Page 48: Installing Lan Module

    The system is equipped with 3 high-performance 32-bit PCI-bus Ethernet interfaces, which are fully compliant with IEEE 802.3/u 10/100Mbps CSMA/CD standards. They are supported by all major network operating systems. Three onboard RJ-45 jacks provide convenient 10/100Base-T RJ-45 operations. RS-200-RT User’s Manual...
  • Page 49: Installing Zero Channel Hw Raid Module

    The machine provides an inexpensive and optional hardware RAID solution without sharing extra PCI slot. Insert the zero-channel hardware RAID module into RAID module socket with 30-degree angle. Please press the module down and let the bracket of module socket latch it. RS-200-RT User’s Manual...
  • Page 50: Adding Disk Drives

    In order to install the hard disk drives in the chassis, please follow the procedures below. Unfasten the dummy HDD tray from the hard disk rack. Put the hard disk drive in the hard rack and fasten it with screws. RS-200-RT User’s Manual...
  • Page 51 Hard Disk drive assembled Slide the cages of the HDD drive into HDD bays and make HDD drive connectors connect the SCSI sockets on SCSI backplane closely. Close the latches RS-200-RT User’s Manual...
  • Page 52: Installing Rail Slider

    2.11 Installing Rail Slider RS-200-RT User’s Manual...
  • Page 53 RS-200-RT User’s Manual...
  • Page 54: Chapter 3 Bios Setup

    3.1 Function Keys The Function Keys are located at the bottom of CMOS setup screen. The keys allow users to navigate then main setup menu. The following table lists describe their functions. RS-200-RT User’s Manual...
  • Page 55 ← or → Select the menu item to the left or the right PU/PD Modify the value or setting Modify the value or setting Enter Select the menu item Display the General Help screen from anywhere in the BIOS Setup Load Previous Values Load Optimized Defaults Save the setting RS-200-RT User’s Manual...
  • Page 56: Main Menu

    3.2 Main Menu When the Setup program is accessed, the following screen appears. Move arrow keys to the appropriate place you will setup and press “Enter” for selection. RS-200-RT User’s Manual...
  • Page 57: Standard Cmos Features

    Date (mm:dd:yy): Set the system date. The format is month, day and year. Move to proper place by arrow keys in order to modify the values by Page Up/+ Key or Page Down/- Key. Time (hh:mm:ss): change internal clock. RS-200-RT User’s Manual...
  • Page 58 IDE Primary Master: Move the highlight to the “IDE Primary Master” and enter to get the following screen. IDE HDD Auto-Detection: To auto-detect the capacity, cylinder, head and sector of HDD RS-200-RT User’s Manual...
  • Page 59 IDE Primary Master: [Auto/Manual/None] Access Mode: [Auto/Large/LBA/CHS] RS-200-RT User’s Manual...
  • Page 60 IDE Secondary Master: [Auto/Manual/None] Access Mode: [Auto/Large/LBA/CHS] IDE Secondary Slave: Choose the option then get the following three items. IDE HDD Auto-Detection: To auto-detect the capacity, cylinder, head and sector of HDD IDE Secondary Slave: [Auto/Manual/None] Access Mode: [Auto/Large/LBA/CHS] RS-200-RT User’s Manual...
  • Page 61 Drive A: Set the type of floppy drive installed by Page Up Key and Page Down. Halt On: Set system halt on when specified item occurs. The selection items are showed in the following screen. RS-200-RT User’s Manual...
  • Page 62: Advanced Bios Features

    Allows the system to skip certain tests while booting. This will decrease the time needed to boot the system. First Boot Device [Floppy/SCSI/CD-ROM/HDD/LAN/Disabled]: Select your boot device priority Second Boot Device [Floppy/SCSI/CD-ROM/HDD/LAN/Disabled]: Select your boot device priority RS-200-RT User’s Manual...
  • Page 63 Gate A20; Normal-a pin in keyboard controller controls Gate A20. Default is set “Fast”. Typematic Rate Setting [Enabled/Disabled]: Keystrokes repeat at a rate determined by keyboard controller. When enabled, the typematic rate and typematic delay can be selected. RS-200-RT User’s Manual...
  • Page 64 MPS Version Control For OS [1.4/ 1.1] OS/2 selection for DRAM > 64MB[Non-OS2/ OS2]: Select OS2 if you are running OS/2 Operating System with greater than 64MB of RAM on the system. RS-200-RT User’s Manual...
  • Page 65: Integrated Peripheral

    Each channel has both a master and a slave, making four IDE devices possible. Because each IDE device may have a different Mode timing (0,1,2,3,4), it is necessary for these to be independent. The default setting “Auto” will allow auto-detection to ensure optimal performance. RS-200-RT User’s Manual...
  • Page 66 Super I/O chip with a FDD controller that supports a FDD Drive for 360K/ 720K/1.2M/1.44M. Choose “Enabled” to use the on-board FDD controller for accessing the FDD. Otherwise choose ”Disabled” to use the off-board FDD controller. Onboard Serial Port 1 [Auto/Disable/(3F8/IRQ4)/(2F8/IRQ3)/(3E8/IRQ4)/(2E8/ IRQ3)] RS-200-RT User’s Manual...
  • Page 67 Internal Alarm Board) 3E8/IRQ4 COM 3 uses IRQ4 2E8/IRQ3 COM 4 uses IRQ3 ECP Mode Use DMA: In ECP Mode Use DMA, you can select DMA channel 1 or DMA channel 3. Leave this field on the default setting. RS-200-RT User’s Manual...
  • Page 68: Pnp/ Pci Configurations

    OS cannot boot. Resources Controlled by [Auto/Manual]: BIOS can automatically configure all the boot and plug & play compatible devices. If you choose Auto, you cannot select IRQ, DMA and memory base address fields, since BIOS RS-200-RT User’s Manual...
  • Page 69 PC with a power failure returns to after power source supplies again. If set to Off, the PC will not boot after power supplies again. If set to On, the PC will boot after power source supplies again. RS-200-RT User’s Manual...
  • Page 70: Load Optimized Defaults

    The option allows you to load the optimized default values for each of the parameters on the Setup menus. When this option is pressed, a confirmation is requested. Select “Y” to load the optimized default values. Select “N” or Press “Esc“ to discard the selection. RS-200-RT User’s Manual...
  • Page 71: Set Password

    If the CMOS is good or if this option has been used to change the default password, the user is asked for the password stored in the CMOS. The screen will display the following message: Confirm Password: Input the current password and press “Enter”. RS-200-RT User’s Manual...
  • Page 72: Save & Exit Setup

    CMOS RAM. The CMOS RAM is sustained by an on board backup battery and stays on even system is turned off. Once the option is selected, a confirmation is asked. Select “Y” to save changes and exit. RS-200-RT User’s Manual...
  • Page 73: Exit Without Saving

    The option should only be used if you do not want to save the changes you have made to the Setup program. If you have made changes to the fields, the system will ask for confirmation before existing. Select “Y” then the system will keep previous values. RS-200-RT User’s Manual...
  • Page 74: Chapter 4 Drivers Installation

    RAID module that can support RAID 0, 1 and 5. Current available drivers for RAID module only support Windows 2000/NT 4.0 and Linux Red-Hat 7.0/7.1. Once the drivers for other OS are available, they will be uploaded to our website. RS-200-RT User’s Manual...
  • Page 75: Drivers For Windows Nt 4.0

    “Setup” or CD auto-run. VGA driver installation Please select the item “RS200-RT Drivers”. Please click “Install VGA driver”, then Choose NT4. Double click “setup.exe”. Please follow the instructions shown on the screens. Restart after driver installation. RS-200-RT User’s Manual...
  • Page 76 3. Insert the “Adaptec 7899 SCSI Driver for Win NT 4.0” diskette into Drive A: and press "ENTER". 4. Select “Adaptec 19160, 29160(N), 39160, AHA-3960D, AIC-7892/7899 Ultra160 PCI SCSI Controller (NT 4.0)” and click “OK”. Follow the normal Windows NT 4.0 setup installation procedure. RS-200-RT User’s Manual...
  • Page 77 7. Specify “a:\”, insert the “Zero-channel RAID driver for Win NT 4.0” diskette into Drive A: and press “Enter” 8. Restart after installation. For more information about how to setup RAID, please retrieve the file RAID_USER_GUIDE.PDF located in the subdirectory RS-200-RT\RAID\ of Driver Bank CD. RS-200-RT User’s Manual...
  • Page 78: Drivers For Windows 2000

    4.2 Drivers for Windows 2000 VGA driver installation Please select the item “RS200-RT Drivers”. Please click “Install VGA driver”, then Choose Win2000. Double click “setup.exe”. Please follow the instructions showed on the screens. Restart after driver installation. RS-200-RT User’s Manual...
  • Page 79 6. Select the “Adaptec I2O RAID Host Adapters for Windows 2000” and click “OK”. Note: for CD-ROM installations, you must also specify the driver for your CD-ROM adapter. Follow the normal Windows 2000 setup installation procedure. Please check other drivers in Driver Bank. RS-200-RT User’s Manual...
  • Page 80: Drivers For Red-Hat Linux 7.0/7.1

    4. When it shows “Insert your driver disk”, please press “OK”. 5. Then, follow the instructions showed on the screens. For more information about how to setup RAID, please retrieve the file RAID_USER_GUIDE.PDF located in the subdirectory RS-200-RT\RAID\ of Driver Bank CD. RS-200-RT User’s Manual...
  • Page 81 RS-200-RT User’s Manual...
  • Page 82: Appendix A Memory Approval List

    SAMSUNG 256MB AR32V72C4S4GAS K4S280432A-TC75 SAMSUNG 512MB AR64V72C4S8GAS K4S560432A-TC75 SAMSUNG AR128V72C4SSGAS SEC 12950-37 Note: All memories belong to PC-133, Registered and ECC type. Memory Module suppliers’ information refers to the website below: ATP Website: www.atpusa.com Smart Website: www.smartmodulartech.com RS-200-RT User’s Manual...
  • Page 83: Appendix B Raid Card Approval List

    Mylex AcceleRAID 352 Appendix C Accessory order information No. P/N Description 9686000073 ZCR HW RAID module 2005S 96960210A0 LAN module for 3 LAN port 9689000425 Rail Slider for RS-200-RT SNMP 100L SNMP 100L SNMP 100N SNMP 100N RS-200-RT User’s Manual...
  • Page 84: Appendix D Safety Instructions

    12. Never pour any liquid into an opening. This could cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened by qualified service personnel only. 14. If any of the following situations arises, get the equipment checked by RS-200-RT User’s Manual...
  • Page 85 The sound pressure level at the operator’s position according to IEC 704-1; 1982 is equal to or less than 70dB(A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. RS-200-RT User’s Manual...
  • Page 86: German- Wichtige Sicherheishinweise

    11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden. 12. Durch die Lüftungsöffnungen drüfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw. RS-200-RT User’s Manual...
  • Page 87 Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70dB(A) oder weiger. DISCLAIMER: This set of instructions is provided according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. RS-200-RT User’s Manual...
  • Page 88: Appendix E Gem318 Driver Installation

    6. You can choose the “SDR GEM318 SCSI Processor Device” by right-clicking your mouse on the file icon, then select “properties” 7. Choose the “Driver” then select “Update Driver” 8. Please specify the “gem318.inf” file in the driver CD disk for driver update. RS-200-RT User’s Manual...

Table of Contents