Systems Insight Display Leds - HP X1000 System User's Manual

Network storage system, swx image version 1.6.0a
Hide thumbs Also See for X1000:
Table of Contents

Advertisement

1. Fault/UID LED (am-
ber/blue)
Amber, flashing regularly (1
Hz)
Off
Amber, flashing regularly (1
Hz)
Off
Steadily amber
Amber, flashing regularly (1
Hz)
Off

Systems Insight Display LEDs

The HP Systems Insight Display LEDs represent the system board layout. The display enables diagnosis
with the access panel installed.
36
Storage system component identification
2. Online/activity LED
(green)
Flashing regularly (1 Hz)
Flashing regularly (1 Hz)
Flashing irregularly
Flashing irregularly
Off
Off
Off
Status
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is part of an array that is undergoing ca-
pacity expansion or stripe migration, but a predictive
failure alert has been received for this drive. To
minimize the risk of data loss, do not replace the
drive until the expansion or migration is complete.
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is rebuilding, or it is part of an array that
is undergoing capacity expansion or stripe migra-
tion.
The drive is active, but a predictive failure alert has
been received for this drive. Replace the drive as
soon as possible.
The drive is active, and it is operating normally.
A critical fault condition has been identified for this
drive, and the controller has placed it offline. Re-
place the drive as soon as possible.
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
The drive is offline, a spare, or not configured as
part of an array.