File Services Management; Configuring Data Storage; Storage Management Utilities; Tasks And Utilities Needed For Storage System Configuration - HP X1000 System User's Manual

Network storage system, swx image version 1.6.0a
Hide thumbs Also See for X1000:
Table of Contents

Advertisement

File services management

Information about the storage system in a SAN environment is provided in the HP StorageWorks SAN
Manuals page located on the HP web site at www.hp.com/go/SDGManuals.

Configuring data storage

HP StorageWorks X1000 and X3000 Network Storage Systems are configured only for the operating
system. The administrator must configure data storage for the storage system.
Configuring additional data storage involves creating arrays, logical disks, and volumes.
shows the general task areas to be performed as well as the utilities needed to configure storage for
an HP Smart Array-based storage system.
Table 14 Tasks and utilities needed for storage system configuration
Task
Create disk arrays
Create logical disks from the array space
Verify newly created logical disks
Create a volume on the new logical disk
Create disk arrays—On storage systems with configurable storage, physical disks can be arranged
as RAID arrays for fault tolerance and enhanced performance, and then segmented into logical
disks of appropriate sizes for particular storage needs. These logical disks then become the volumes
that appear as drives on the storage system.
CAUTION:
The single logical drive is configured for the storage system operating system and should not be
altered in any manner. If the operating system logical drive is altered, the system recovery process
may not function properly when using the System Recovery DVD. Do not tamper with the local C:
volume. This is a reserved volume and must be maintained as it exists.
The fault tolerance level depends on the amount of disks selected when the array was created. A
minimum of two disks is required for RAID 0+1 configuration, three disks for a RAID 5 configuration,
and four disks for a RAID 6 (ADG) configuration.
Create logical disks from the array space—Select the desired fault tolerance, stripe size, and size
of the logical disk.
Verify newly created logical disks—Verify that disks matching the newly created sizes are displayed.
Create a volume on the new logical disk—Select a drive letter and enter a volume label, volume
size, allocation unit size, and mount point (if desired).

Storage management utilities

The storage management utilities preinstalled on the storage system include the HP Array Configuration
Utility (ACU).
56
File server management
Storage management utility
HP Automated Storage Manager or HP Array Configuration
Utility
HP Automated Storage Manager or HP Array Configuration
Utility
Windows Disk Management
Windows Disk Management
Table 14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3000X1400X3400X1500X1600X1800 ... Show all

Table of Contents