Direct Wire
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral
wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Power
Svpp[y Cor_ Co_e¢_io_
Power supply cord strain relief
Remove
the screws
from
a 3/_" (19 mm) UL listed
strain
relief
(UL
marking
on strain
relief).
Put the tabs of the two clamp
sections
(C)
into the hole below
the terminal
block
opening
(B) so that one tab
is
pointing
up (A) and the other is pointing
down
(D), and hold
in place.
Tighten
strain
relief
screws just enough
to hold
the two clamp
sections
(C) together.
B
E
C
i!
Before
you start,
disconnect
power.
Remove
hold-down
screw
(D) and
terminal
block
cover
(A).
A.
Terminal
block
cover
B.
External
ground
conductor
screw
C. Center
terminal
block
screw
D. Hold-down
screw
E.
Neutral
ground
wire
F.
Hole below
terminal
block
cover
relief
Put power
supply
cord
through
the strain
relief.
Be sure that the wire
insulation
on the power
supply
cord
is inside
the strain
relief.
The
strain
relief
should
have
a tight
fit with
the dryer
cabinet
and be in
a horizontal
position.
Do not further
tighten
strain
relief
screws
at this
point.
If your outlet looks llke this:
Power supply
cord
4-wire
receptacle
(NEMA
Type 14-30R):
Go to "4-Wire
Power Supply
Cord
Connection"
on page
9.
if your out_et looks llke this:
Power supply
cord
3-wire
receptacle
(NEMA
Type 10-30R):
Go to "3-Wire
Power Supply
Cord
Connection"
on page
9.
8