Kenmore 29" Installation Instructions Manual page 9

29" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

4owire
Power
Supply
Cord Connection
IMPORTANT:
A 4-wire
connection
is required
for mobile
homes
and
where
local
codes
do not permit
the use of 3-wire
connections.
4-wire
receptacle
(NEMA
type
14-30R)
4-prong
plug
Spade
terminals
with
upturned
ends
Ring terminals
Connect
ground
wire
(F) (green
or bare)
of power
supply
cord
to
external
ground
conductor
screw
(A). Tighten
screw.
Prepare
to connect
neutral
ground
wire and neutral wire
Remove
center
terminal
block
screw
(B). Remove
neutral
ground
wire
(E) from
external
ground
conductor
screw
(A).
Connect
neutral
ground
wire and
neutral
wire
Connect
neutral
ground
wire
(E) and
neutral
wire (white)
(C) of power
supply
cord
under
center
terminal
block
screw
(B). Tighten
screw.
Connect
remaining
wires to outer
terminal
block
screws.
Tighten
screws.
Finally,
reinsert
tab
of terminal
block
cover
into slot of dryer
rear
panel.
Secure
cover
with
hold-down
screw.
Now,
go to '_Venting
Requirements/_
3owire
Power Supply
Cord Connection
Use where
local
codes
permit
connecting
cabinet-ground
conductor
to
neutral
wire.
3-wire
receptacle
(NEMA
type
I0-30R)
3-prong
plug
Spade
terminals
with
upturned
ends
Ring terminals

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

29" wide electric models

Table of Contents