Page 1
Australian Monitor I N S T A L L A T I O N S E R I E S Clever Features, Contractor Friendly ZoneMix3 3 Zone Stereo Mixer/Matrix Installation & Operation Manual Australian Monitor ZONE 1 ZONE 2 ZONE 3...
Page 2
WARNING ! posure. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK. To prevent electric shock, match wide blade of plug to DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. wide slot, fully insert. Australian Monitor INSTALLATION SERIES...
Featuring a broadcast quality audio spec, the Zone Mix 3 allows selection of 4 stereo sources to 3 stereo zones either at the ZoneMix3 or remotely. One stereo source can have selectable priority per zone & each stereo zone boasts 5 stage equalization. The Zone Mix 3 also has the ability to route two independent mic or line signals to any zone or combination of zones.
2. FRONT PANEL Australian Monitor ZONE 1 ZONE 2 ZONE 3 PAGE MIC PROG TRIM 100Hz 300Hz 1kHz 3kHz 10kHz 100Hz 300Hz 1kHz 3kHz 10kHz 100Hz 300Hz 1kHz 3kHz 10kHz INSTALLATION SERIES GAIN BASS TREBLE PROG 1 PROG 2 PROG 3...
Page 6
(ie when the amplifier is clipping) rather than indicate clip within the ZoneMix3. When used with Australian Monitor Synergy amplifiers, both LEDS on the ZoneMix3 and the Synergy amplifier will go red simultaneous indicating system clip (with pot at full on amplifier). 6. REMOTE This LED indicates that the zone is in remote control mode.
LINE4 is a priority input, if this feature is enabled. See Internal Adjustments on page 10 and Functional Notes on page 9 5. ZONE OUTPUTS The zone outputs are configured as stereo left and right as default but can be internally changed to mono. Australian Monitor INSTALLATION SERIES...
Page 8
8. LINK This 15 pin high density connector is used to connect two ZoneMix3 units together. When connected together the program sources and the mic/line inputs are linked to the slave unit.
Our DigiPage and DigiPageJr family of products allow for comprehensive paging and program distribution into up to 16 zones. Please contact your local AMIS dealer for more details. Australian Monitor INSTALLATION SERIES...
Chime Level Adjust There are many internal adjustments that can be made to configure the ZoneMix3 to perform exactly as you want it. Use the diagram above to locate various controls and refer to the section indicated for a more detailed view and information on that control.
Page 11
This pot is for the chime that sounds when a page is made using the Paging Station. Paging Chime level 0dB to Off - Defaults is -6dB. SECTION C This section is repeated 3 times (one per zone). Zone Eq Bypass switch - Eq In/Eq Out. Default is Eq In. Australian Monitor INSTALLATION SERIES...
Page 12
Output Mode switch - Mono/Stereo. Default is Stereo. SECTION E These two sockets are used when linking two ZoneMix3 units. See Functional Notes on page 9 for explanation of linking. All input sources are connected to the Master unit. In this unit the linking header should be plugged into the connector labelled LINK-MASTER.
FEMALE XLR REMOTE CONTROLS The remote control options on the ZoneMix3 are quite extensive and permit many possible situations to be accommodated. Remote control is achieved via the rear panel RJ45 (CAT5) socket. Below is a diagram of the pin out on the CAT5 cable.
Page 14
(for Left sub zone send). The zone should be set to MONO, see Internal Adjustments on page PAGING STATION See Paging Station on page 16 for more inforamtion. Connect cable from ZM3M to PAGE MIC connector on the ZM3. Australian Monitor INSTALLATION SERIES...
This will allow remote source selection & zone volume adjustment. 10. The ZM3 features 5 band equalization to achieve precise equalization of high quality audio systems in demanding environments. Repeat this process for the other 2 zones. Australian Monitor INSTALLATION SERIES...
1 ZONE select 115.0mm These buttons, when pressed, will page to that zone. With the button held down, talk into the Australian Monitor ZM3M microphone. There is a label space to the INSTALLATION SERIES right of the button to allow labelling of the zone.
NE8MC) to improve reliability. Normal RJ45 connectors can also be used. CABLE INSTALLATION FOR PAGING STATION The RJ45 port (labelled Page Mic) on the rear of the ZoneMix3 is provided for connection to a ZoneMix3 Zone Paging Station, ZM3M. The CAT5 cable can be up to 30m long and should be routed as best as possible away from sources of high electromagnetic radiation (such as motors and dimmers).
& volume control from a remote zone. It features ample label space and a contemporary black decor. Running via industry standard CAT5 cable, the ZM3R is another product from Australian Monitor Installation Series that provides a simple yet elegant solution to a complex zoning application.
Page 19
Ensure that the RJ45 connectors are suited to the cable used (solid or stranded) and that the correct crimp tool is used. NOTE: These are Ethernet connections. Australian Monitor INSTALLATION SERIES...
Page 20
Dimensions 51 mm Panel (ZM3R) 75 mm Surface Mount Box 35 mm 44 mm 80 mm Australian Monitor INSTALLATION SERIES...
10. DIMENSIONS 482.0 mm 467.0 mm Australian Monitor ZONE 1 ZONE 2 ZONE 3 PAGE MIC PROG TRIM 100Hz 300Hz 1kHz 3kHz 10kHz 100Hz 300Hz 1kHz 3kHz 10kHz 100Hz 300Hz 1kHz 3kHz 10kHz INSTALLATION SERIES GAIN BASS TREBLE PROG 1 PROG 2...
PROG LEVEL REMOTE MIC1 ENABLED ZONE 3 Z3 PROG SEL MIC 1 ZONE 3 ZONE 3 SELECT SELECT ZONE 3 MIC2 PROG MUTE PROG 4 CONTROL MIC 2 MUTE RELEASE TIME SELECT SELECT CONTROL PRIORITY OFF,1,2,3,4 Australian Monitor INSTALLATION SERIES...
-Max Level Out: 10Vrms (+22dB) -Frequency Response: 20Hz - 20kHz (0dB/-3dB) -THD: less than 0.1% -Noise: -80dB -Crosstalk: Better than 65dB -Phantom Power: 15VDC All measurements referenced to 0dBu (0.775mV) All measurements done with levels set to max Australian Monitor INSTALLATION SERIES...
Page 24
149 Beaconsfield Street, Silverwater NSW 2128 Australia Ph: 61-2- 9647 1411 Fax: 61-2-9748 2537 E-mail: international@audiotelex.com.au USA/CANADA/SOUTH AMERICA www.australianmonitor.com Australian Monitor Audio Inc. PO Box 3126, Lynnwood, WA 98046 Ph: 425 673 5175 Fax: 425 673 7825 E-mail: sales@australianmonitor.com SUM IN ZONE 3...
Need help?
Do you have a question about the ZoneMix3 and is the answer not in the manual?
Questions and answers