Page 2
IMPORTANT INFORMATION NOTES: Read prior to activation You have just purchased a complicated electronic device. To operate it properly, please read this manual carefully. Here are some common precautions that must be noted. • NEVER subject the unit to impact while operating or being transported •...
Features of the LRM 1200 / LRM 1500 / LRM 1500SPD 10. QUALITY CERTIFICATE Laser Range Finder Monocular • Latest digital circuitry allows targeting through most types The LRM 1200 / LRM 1500 / LRM 1500SPD is suited for of glass • usage. 'Last Target' measurement •...
9am-5pm, Monday - Friday, Standard East Time. 1. BRIEF DESCRIPTION At no time should equipment be sent back to Newcon LRM 1200 / LRM 1500 / LRM 1500SPD Laser Range Finder without following the instructions of our technical Monocular is advanced Laser Range Finder system that support department.
7 – Body of the device; 8 – Rubber grip service are your responsibility. Please include a check or money order made out to NEWCON OPTIK for the amount of $15.00 to Fig. 1 cover shipping and handling. This covers products shipped in...
The range-measuring mode does not work. Patent pending Press the Action Button again. Newcon Optik Check that the batteries are installed properly. Check the charge Made in Canada of the batteries. Replace if they are weak. Do not use old batteries with new ones.
Type Class 1, eye safe, 905nm • Do not keep the device at temperatures higher than 50 Finder Measuring Range, m - LRM 1200 20 – 1,200 (122 - LRM 1500, LRM 1500SPD 20 – 1,500 • Do not touch the optical surfaces with fingers. Doing so Accuracy ±...
5. OPERATION INSTRUCTIONS The displayed statistical qualification of the reflected signal Liquid Crystal Display (LCD) characterizes variation in expected accuracy of measurements. At qualification HIGH the accuracy of measurements is stated as ±1m ± 0.1%. At lower rates of statistical qualification the expected accuracy may marginally degrade.
5.1. Preparing the Device for Operation. c. Reflection • Unscrew the screw (10) and open battery compartment cover Distance measuring procedure includes instant statistical (9) (fig. 2). processing of the package of single measuring sessions. • Insert one 9V battery (sold separately) into the battery Qualitative result of the statistical processing is presented on the compartment observing correct polarity.
Page 10
Y/M – units of measurement: yards or meters (3). The maximum measuring range for most objects will be 1200m KMH/MPH – units of speed measurement: km/hour or with LRM 1200 and 1512m with models LRM 1500 and LRM miles/hour (3). 1500SPD. The maximum measured distance will vary greatly Please note: this is feature is provided with LRM 1500SPD only.