The T‐H2‐DV/T‐H2‐OS provides the four types of the pump control 
modes.  The pump control modes are selected by changing 
dipswitch settings. The dipswitches that change the pump control 
modes are located in the right bank of dipswitches in the upper‐
left quadrant of the computer board in the T‐H2‐DV/T‐H2‐OS. (See 
right.)  These 4 modes only affect pumps that are connected to 
the T‐H2‐DV/T‐H2‐OS pump control (p.25) 
 
 
A) Recirculation Control: No. 5 ON 
 
Feature:  Maintaining temperature in a standard recirculation loop, providing hot water in a quicker 
amount of time. 
 
Function: The pump is only set to run when the temperature of the water in the recirculation loop is 
more than 9°F below the set temperature of the T‐H2‐DV/T‐H2‐OS.  
The pump will run for about 1 minute every 30 minutes to determine whether the water 
temperature in the entire recirculation loop is more than 9°F below the set temperature. 
If the water temperature is more than 9°F below the set temperature, the pump will remain running 
until the water in the loop reaches the set temperature. Otherwise, the pump will stop for another 
30 minutes.  
If the inlet thermistor of water heaters detects that the water temperature is more than 9°F below 
the set temperature before those 30 minutes have elapsed, the pump will activate immediately and 
remain running until the water in the loop reaches the set temperature.
 
 
B) Storage Tank Circulation Control: No.6 ON 
 
Feature: This is to ensure a higher rate of recovery for storage tank applications. 
 
Function:  The  T‐H2‐DV/T‐H2‐OS  heats  the  water  5.4°F  higher  than  its  set  temperature.  The 
circulation  pump  between  the  storage  tank  and  the  water  heater  will  continually  remain  running. 
After set temperature has been reached in the storage tank, the T‐H2‐DV/T‐H2‐OS will fire off and 
limit the water flow rate to less than 2.6 GPM, to continually monitor the temperature throughout 
the system. 
 
Note: In this mode, the pump will continually remain running.
 
 
C) Energy Conserving Recirculation: No.5 and No.6 ON 
 
Feature: Operates similarly to the standard Recirculation Control mode, but saves more energy by 
limiting the temperature within the recirculation loop. 
 
Function: The temperature of the recirculation loop is never kept above 120°F (49 °C), regardless of 
the set temperature of the T‐H2‐DV/T‐H2‐OS. 
 
 
 
 