Liebert GXT2U User Manual

Liebert GXT2U User Manual

120v, 500-3000va
Hide thumbs Also See for GXT2U:

Advertisement

DISCONTINUED
PRODUCT
Liebert
User Manual - 120V, 500-3000VA
GXT2U
®
AC Power Systems
For Business-Critical Continuity™

Advertisement

Table of Contents
loading

Summary of Contents for Liebert GXT2U

  • Page 1 DISCONTINUED PRODUCT AC Power Systems For Business-Critical Continuity™ Liebert GXT2U ® ™ User Manual - 120V, 500-3000VA...
  • Page 2 DISCONTINUED PRODUCT...
  • Page 3: Table Of Contents

    Dynamic Bypass ....... . 6 Liebert GXT2U, Rear View ..... . . 7 .
  • Page 4 ONFIGURATION ROGRAM Liebert GXT2U Configuration Program Abilities ..23 8.1.1 What You Will Need ......23 .
  • Page 5: Save These Instructions

    Maximum load must not exceed that shown on the UPS rating label. The UPS is designed for data processing equipment. If uncertain, consult your local dealer or Liebert representative. This UPS is designed for use on a properly grounded (earthed), 50Hz or 60Hz, 120V supply (programmable for 100, 110, 115, 120 and 127VAC output).
  • Page 6 Turn the UPS off and isolate the UPS before cleaning; use only a soft cloth, never liquid or aerosol cleaners. Keep the front and rear vents free of dust accumulation that could restrict airflow. When replacing batteries, replace with the same Liebert authorized replacement battery kits. CAUTION Do not dispose of battery or batteries in a fire.
  • Page 7: Glossary Of Symbols

    Glossary of Symbols LOSSARY OF YMBOLS Risk of electrical shock Indicates caution followed by important instructions AC input AC output Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage Standby...
  • Page 8: Introduction

    The Liebert GXT2U protects equipment from these disturbances. The Liebert GXT2U comes in nominal power ratings of 500, 700, 1000, 1500, 2000 and 3000 VA. Complete model specifications appear at the end of this manual.
  • Page 9: Major Components

    • The amount of distortion reflected on the utility is reduced. This results in cleaner power being available to other devices in the building not being protected by the Liebert GXT2U. NVERTER In normal operation, the inverter utilizes the DC output of the power factor correction circuit and inverts it into precise, regulated sinewave AC power.
  • Page 10: Battery Charger

    YNAMIC YPASS The Liebert GXT2U provides an alternate path for utility power to the connected load in the unlikely event of a UPS malfunction. Should the UPS have an overload, overtemperature, or UPS failure condition, the UPS automatically transfers the connected load to bypass.
  • Page 11: Liebert Gxt2U, Rear View

    Major Components GXT2U, R IEBERT USB card being fitted ® in Liebert IntelliSlot Rev. USBCARD Port DB-9 Communications Port Cooling Fan Input Fuse/Circuit External Battery Breaker Connector Output Receptacles AC Input Support Base DISCONTINUED PRODUCT...
  • Page 12: Installation

    The UPS is heavy (see 11.0 - Specifications). Take proper precautions when lifting or moving it. 2. Decide where to place the Liebert GXT2U. Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives, and conductive contaminants.
  • Page 13: Rack-Mount Ups Conversion And Installation

    UPS. Optional rack mount handles Securing hardware and slide rails are sold separately. Contact your local dealer or Liebert representative for these additional options and any assistance needed. 2. Unpack the two (2) rack-...
  • Page 14 Installation 3. Determine the height position inside the rack enclosure where you want to mount the UPS or battery cabinet. CAUTION Reduce risk of tipping the rack enclosure by placing UPS or battery cabinet in the lowest possible rack position. Install rear member of each M5 screws bracket assembly into rack...
  • Page 15 Installation 5. Prepare the UPS or battery cabinet (the “equipment”) for Retaining screws latch rack mounting by following instructions in the equipment’s user manual. The equipment may require additional parts to UPS or battery be added or parts to be removed cabinet for rack mounting.
  • Page 16 Installation 8. Secure front of the equipment to rack mounting rails to prevent the equipment from sliding out of position. If securing holes are provided on front of the equipment that align with the center holes on return flange of front members, you can use the four (4) extra M5 screws provided in this kit to secure the equipment.
  • Page 17: External Battery Cabinet Installation

    ATTERY ABINET NSTALLATION Optional Liebert external battery cabinets may be connected to the UPS to provide additional battery run time. External battery cabinets are designed to be placed all on one side of the UPS or stacked beneath the UPS. There is no limit to the number of external battery cabinets that can be used but each cabinet will increase the battery recharge time.
  • Page 18: Controls And Indicators

    ON - Pressing this button will start up the UPS in order to provide conditioned and protected power. Alarm Silence - To silence alarms, press this button for at least one second. After the alarm is silenced, the Liebert GXT2U will reactivate the alarm system to alert of additional problems. NOTE The LOW BATTERY and BYPASS reminder alarms CANNOT be silenced.
  • Page 19: Standby/Manual Bypass Button

    UPS; and during battery mode operation LED indicators display approximate battery capacity. The Liebert GXT2U is equipped with automatic and remote battery test features. The automatic test occurs every 14 days (this option is user configurable) if utility has not been interrupted. Should the bat-...
  • Page 20: Ac Input Indicator Led (Green)

    The Output Voltage is user configurable and is designed to allow selecting or changing the desired output voltage to match the utility via the Liebert GXT2U Configuration Program provided with the UPS. The settings to choose from are 100, 110, 115, 120, and 127 VAC output.
  • Page 21: Operating Instructions

    Operating Instructions PERATING NSTRUCTIONS ORMAL PERATION During normal operation, utility power provides energy to the UPS. The filters, power factor correction circuit and the inverter process this power to provide computer AC INPUT BATTERY UPS ON BYPASS grade power to connected loads.
  • Page 22: Battery Mode Operation

    If the UPS is turned OFF by a communication signal or because the batteries are depleted, it will operate as selected in the configuration program for Auto-Restart (see 8.1 - Liebert GXT2U Configuration Program Abilities). ATTERY ECHARGE Once utility power is restored, the UPS resumes normal operation.
  • Page 23: Communications

    Communications OMMUNICATIONS OMMUNICATIONS NTERFACE The Liebert GXT2U UPS has a standard DB-9 serial port female con- nector located on the rear of the UPS unit. Several signals are pro- vided on this port and are assigned as follows: Assignment Description...
  • Page 24: Pins 4 & 5 - Remote Shutdown On Battery

    2. Pin 4 requires a 5-12 VDC signal to shutdown. This normally comes form the serial port using Liebert’s contact closure cable. It cannot be used with just a contact closure unless the relay is used to switch a voltage source. A 5-12 VDC signal for 1.5 seconds or greater is required to signal a shutdown.
  • Page 25: Pins 5 & 6 - Any-Mode Shutdown

    If version 1.6 (or later) is used with an earlier Liebert GXT2U model (with an earlier UPS firmware version), the Any-Mode Shutdown fea- tures cannot be changed.
  • Page 26: Ups Intelligent Communications

    • The Liebert IntelliSlot SNMP/Web Card provides SNMP and Web- based monitoring and control of the UPS across the network. • The Liebert IntelliSlot MultiPort 4 Card allows you to install Lie- bert MultiLink software on four computers and coordinate shut- down in the event of a power failure.
  • Page 27: Configuration Program

    Configuration Program ONFIGURATION ROGRAM The configuration program included with the Liebert GXT2U line allows modification of several UPS settings that were previously unavailable or required custom manufacturing. The user manual on the configuration program disk describes the features available for modification, as well as default settings.
  • Page 28: Maintenance

    UPS in for at least 24 hours every four to six months to ensure full recharge of the batteries. The Liebert GXT2U is designed to allow the user to safely replace the internal batteries. Read the safety cautions before proceeding. Contact your local dealer or Liebert representative to obtain the appropriate replacement battery kit part number and pricing.
  • Page 29: Internal Battery Replacement Procedures

    Compare new and old battery assemblies to make sure they are the same. If so, proceed with Step 6; otherwise STOP and contact your local dealer, Liebert representative, or the Liebert Worldwide Support Group. 6. Line up and slide in the new replacement battery pack.
  • Page 30: Fuse Replacement

    Maintenance EPLACEMENT CAUTION Before changing the input fuse, turn off the UPS, and unplug the supply lead from the AC input supply. Replace the fuse with the same type and rating. 1. Remove the input fuse. 2. Locate the spare input fuse that is included with the UPS.
  • Page 31: Troubleshooting

    10.0 T ROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the Liebert GXT2U develops a problem. Use this information to determine whether external factors caused the problem and how to remedy the situation. 1. The Fault indicator will illuminate, indicating the UPS detected a problem.
  • Page 32: Table 1 Troubleshooting Guide

    If a problem persists, consult your local dealer, Liebert representative or contact the Liebert Worldwide Support Group. Please have the UPS model number and serial number available at the time of your inquiry.
  • Page 33 Liebert Representative or LED E are the Liebert Worldwide illuminated. Support Group. Fault indicator Replace batteries. Contact LED and your local dealer, Liebert diagnostic LED A UPS failed the battery test. representative or the and C are Liebert Worldwide Support illuminated. Group.
  • Page 34 For LED C and E are communications port(s). assistance, contact your illuminated. local dealer, Liebert representative or the Liebert Worldwide Support Group. UPS detected a line-to- neutral reversal or a loss of proper grounding;...
  • Page 35: Table 2 Alarm Conditions

    Troubleshooting Table 2 Alarm conditions Condition Alarm Battery Mode One short beep every 10 seconds; (utility failure) more than 2 minutes of run time remaining Two short beeps every 5 seconds; Low Battery less than 2 minutes of run time remaining Output Overload One short beep every half second (bypass)
  • Page 36: Specifications

    Specifications 11.0 S PECIFICATIONS Model Number GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 Model Rating 500VA/350W 700VA / 490W 1000VA / 700W DIMENSIONS - in. (mm) Unit 3.5 x 21.5 x 17 3.5 x 21.5 x 17 3.5 x 21.5 x 17 W x D x H (87 x 547 x 430) (87 x 547 x 430) (87 x 547 x 430)
  • Page 37: Specifications

    Specifications PECIFICATIONS CONTINUED Model Number GXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 Model Rating 1500VA / 1050W 2000VA / 1400W 3000VA / 2100W DIMENSIONS - in. (mm) Unit 3.5 x 21.5 x 17 3.5 x 21.5 x 17 3.5 x 24.2 x 17 W x D x H (87 x 547 x 430) (87 x 547 x 430) (87 x 618 x 430)
  • Page 38: Battery Cabinet Specifications

    Battery Cabinet Specifications 12.0 B ATTERY ABINET PECIFICATIONS Model Number GXT2-48VBATT GXT2-72VBATT GXT2-500RT120 GXT2-700RT120 Used With GXT2-1000RT120 GXT2-3000RT120 UPS Model GXT2-1500RT120 GXT2-2000RT120 DIMENSIONS - in. (mm) Unit 3.5 x 21.5 x 17 3.5 x 24.2 x 17 W x D x H (87 x 547 x 430) (87 x 618 x 430) Shipping...
  • Page 39: Battery Run

    Battery Run Times 13.0 B ATTERY IMES Load% 500VA 700VA 1000VA 1500VA 2000VA 3000VA Internal Battery (minutes) 100% 1976 Internal Battery + 1 External Battery Cabinet (minutes) 100% 3953 1984 1528 1152 1453 Internal Battery + 2 External Battery Cabinets (minutes) 100% 5929...
  • Page 40: Product

    EGISTRATION To register for warranty protection: • Visit the Quick Links section of our Web site at: http://www.liebert.com • Click on Product Warranty Registration and fill in the form. If you have any questions, please contact us at: US: 800-222-5877 Outside the US: 614-841-6755 upstech@liebert.com...
  • Page 41 NOTES DISCONTINUED PRODUCT...
  • Page 42 DISCONTINUED PRODUCT...
  • Page 43 DISCONTINUED PRODUCT...
  • Page 44 Fax: 852 28029250 614-888-0246 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

Table of Contents