4.2 Port Status
This function allows displaying each port's status. On means the port is supplying 48VDC
power where Off means the port is disconnected or is disabled. As showed in Figure
4-3.
Figure 4-3 Port status screen
4.3 PoE Power Class
This function displays the PoE PD power classification. As showed in Figure 4-4.
Figure 4-4 PD power classification screen
A PD may be classified by the PSE based on the classification information provided by the
PD. The intent of PD classification is to provide information about the maximum power
required by the PD during operation.
Class 0 is the default for PDs. However, to improve power management at the PSE, the PD
may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum power
that the PD will draw across all input voltages and operational modes. A PD shall return
Class 0 to 3 in accordance with the maximum power draw as specified by table below.