Introduction; System Overview; Features And Benefits - Eaton C440/XTOE User Manual

Electronic overload relay, devicenet
Hide thumbs Also See for C440/XTOE:
Table of Contents

Advertisement

Introduction

System Overview

Eaton's new electronic overload relay (EOL) is the most
compact, high-featured, economical product in its class.
Designed on a global platform, the new EOL covers the entire
power control spectrum including NEMA
DP contactors. The NEMA and DP versions are offered with the
C440 designation while the IEC offering has the XT designation.
The electronic design provides reliable, accurate and value
driven protection and communications capabilities in a single
compact device. It is the flexible choice for any application
requiring easy-to-use, reliable protection.
Eaton has a long history of innovations and product
development in motor control and protection, including both
traditional NEMA, as well as IEC control. It was from this
experience that the C440 was developed, delivering new
solutions to meet today's demands.
C440 is a self-powered electronic overload relay available up
to 100A as a self contained unit. With external CTs, C440 can
protect motor up to 1500 FLA. Available add-on accessories
include remote reset capability and communication modules
with I/O for DeviceNet™, PROFIBUS
Features and Benefits
Features
Reliable, accurate, electronic motor protection
Easy to select, install and maintain
Compact size
Flexible, intelligent design
Global product offering—available with NEMA, IEC, and
DP power control
Size/Range
Broad FLA range (0.33–1500A)
Selectable trip class (10A, 10, 20, 30)
Direct mounting to NEMA, IEC, and DP contactors
Most compact electronic overload in its class
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
®
, IEC, and
®
, and Modbus
®
.
C440/XTOE Electronic Overload Relay, DeviceNet MN04210002E—March 2011 www.eaton.com
Motor Control
Two B600 alarm (NO) and fault (NC) contacts
Test/Trip button
Motor Protection
Thermal overload
Phase loss
Selectable (ON/OFF) phase unbalance
Selectable (ON/OFF) ground fault
User Interface
Large FLA selection dial
Trip status indicator
Operating mode LED
DIP switch selectable trip class, phase unbalance, and
ground fault
Selectable Auto/Manual reset
Feature Options
Remote reset
120 Vac
24 Vac
24 Vdc
Tamper-proof cover
Communications modules
Modbus RTU RS-485
DeviceNet with I/O
PROFIBUS with I/O
Modbus RTU with I/O (Q4 2010)
Ethernet IP (planned)
Introduction