Circuit Requirements; 220V Operation; Grounding - Grizzly G8621 Instruction Manual

Heavy-duty sliding table shaper
Hide thumbs Also See for G8621:
Table of Contents

Advertisement

SECTION 2: CIRCUIT REQUIREMENTS

220V Operation

The Model G8621 Shaper is furnished with a
3450 R.P.M., 5 H.P., Single-Phase 220V motor,
push-button ON/OFF magnetic starter switch, for-
ward-reverse switch and a cord set. Under nor-
mal use, the motor draws approximately 25 amps
@ 220V. We recommend a 30 amp circuit break-
er. If frequent circuit failures occur when using the
shaper, contact our service department.
The shaper motor must be connected to its own
dedicated 30A circuit. The shaper should not
share a circuit with any other machine, and the
wires in the circuit should be rated for 30A. A
standard 2-pole breaker is also necessary for use
with the shaper.
We recommend using a NEMA-style L6-30 plug
and outlet similar to that in Figure 1. You may
also "hard-wire" the shaper directly to your panel,
provided you place a disconnect near the
machine. Check the electrical codes in your area
for specifics on wiring requirements.
Figure 1. 220V Single-Phase
G8621 Heavy-Duty Sliding Table Shaper

Grounding

In the event of an electrical short, grounding
reduces the risk of electric shock by providing a
path of least resistance to disperse electric cur-
rent. This tool is equipped with an electric cord
that has an equipment-grounding conductor
which must be properly connected to a grounding
plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Improper connections of the electrical-grounding
conductor can result in the risk of electric shock.
The conductor with green or green and yellow
striped insulation is the electrical-grounding con-
ductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the
equipment grounding conductor to a live terminal.
This equipment must be
grounded. Verify that any
existing electrical outlet
and circuit you intend to
plug
grounded. Under no cir-
cumstances should the
grounding pin from any
three-pronged
removed. Serious injury
may occur.
into
is
actually
plug
be
-5-