Motor & Electrical
symptom
possible Cause
Machine does not
1. plug/receptacle is at fault or wired incorrectly.
start or a breaker
2. Motor connection wired incorrectly.
trips.
3. Wall fuse/circuit breaker is blown/tripped.
4. power supply switched oFF or is at fault.
5. Wiring is open/has high resistance.
6. Motor on/oFF switch is at fault.
7. Motor is at fault.
Machine stalls or
1. Feed rate/cutting speed too fast for task.
is overloaded.
2. Machine is undersized for the task.
3. Blade is slipping on wheels.
4. Motor connection is wired incorrectly.
5. plug/receptacle is at fault.
6. pulley/sprocket slipping on shaft.
7. Motor is at fault.
Machine
has
1. Motor or component is loose.
vibration or noisy
operation.
2. Blade weld is at fault or teeth are broken.
3. Blade is at fault.
4. V-belt worn or loose.
5. pulley is loose.
6. Motor mount loose/broken.
7. Machine is incorrectly mounted or sits
unevenly.
8. Motor fan is rubbing on fan cover.
9. Motor bearings are at fault.
g0659 9" x 14" Vertical Metal-Cutting Bandsaw

Troubleshooting

possible solution
1. test for good contacts; correct the wiring.
2. Correct motor wiring connections.
3. ensure circuit size is suitable for this machine;
replace weak breaker.
4. ensure power supply is switch on; ensure power
supply has the correct voltage.
5. Check for broken wires or disconnected/corroded
connections, and repair/replace as necessary.
6. replace faulty on/oFF switch.
7. test/repair/replace.
1. decrease feed rate/cutting speed (page 19/page
30).
2. use sharp blade with lower tpi; reduce the feed
rate/depth of cut.
3. Adjust blade tracking and tension to factory
specifications (page 29/page 26).
4. Correct motor wiring connections.
5. test for good contacts; correct the wiring.
6. replace loose pulley/shaft.
7. test/repair/replace.
1. inspect/replace stripped or damaged bolts/nuts, and
re-tighten with thread locking fluid.
2. replace blade.
3. replace warped, bent, or twisted blade; resharpen
dull blade.
4. inspect/replace belt.
5. realign/replace shaft, pulley, setscrew, and key as
required.
6. tighten/replace.
7. tighten/replace anchor studs in floor; relocate/shim
machine.
8. replace dented fan cover; replace loose/damaged
fan.
9. test by rotating shaft; rotational grinding/loose shaft
requires bearing replacement.
-37-