REALTIME CONTROL MODULE

CONTROL 7 - Function: ATTACK RATE

1. ATK RATE controls the VCA attack rate. To assign this destination to the control source
(selected as per GENERAL INSTRUCTIONS 6), key in 7.
Application hint: When assigned to the Right wheel, rotating the wheel away from you
increases the attack time. This effect is useful when changing from legato to percussive
effects, especially with sustained sounds such as strings.
Note: With ATK RATE assigned to a wheel, VCA/LFO module function 1A (VCA attack)
and Filter module function 3A (filter attack) are disabled. Therefore, Filter and VCA
attack rates are determined solely by the wheel setting.

FOOTSWITCH 0 - Function: OFF

1. To turn off the footswitch (selected as per GENERAL INSTRUCTIONS 6), key in 0.

FOOTSWITCH 1 - Function: SEQ CTRL

1. To start and stop the Sequencer via footswitch, after selecting the desired footswitch key
in 1.

FOOTSWITCH 2 - Function: SUSTAIN

1. For footswitch controlled sustain, after selecting the desired footswitch (as per
GENERAL INSTRUCTIONS 6) key in 2.
Note: If you play a looped sound while the footswitch is pressed, as soon as the looped
portion begins it will sustain (even after lifting your fingers off the keys) until the
footswitch is released. Holding down the footswitch continuously provides a hold function
for looped notes, where the last eight notes played will sustain for as long as the
footswitch is pressed.
If you play an unlooped sound while the footswitch is pressed, it will play through its
entire length (whether or not you are holding down a key), then stop.