Ba Amplifier Dimensions - Aerotech BA10 SERIES User Manual

Table of Contents

Advertisement

BA10/20/30 Series User's Manual
3.3.

BA Amplifier Dimensions

The outline dimensions for the BA amplifiers are shown in Figure 3-1 and Figure 3-2.
To ensure proper heat dissipation, Aerotech recommends the following procedures.
1.
Use the mounting procedure shown in Figure 3-3. The wider part of the amp should
be mounted to the heat sink.
2. Heat sink should be at least 2 feet
3.
The heat sink should be free of paint or any other thermal
4.
The heat sink must be flat to allow good thermal conductivity between the heat sink
and the amplifier.
5.
If possible, add a thermal conductivity enhancer (i.e., thermal grease between the
heat sink and the amplifier).
6.
Adding an external fan will remove a considerable amount of heat from the heat sink
and allow the amplifier to operate at a much cooler temperature.
31.8 [1.25]
TYP.
25.4 [1.00]
TYP.
Version 1.6
2
x0.25 inch thick minimum.
2 FT
177.8 [7.00]
TYP.
$(527(&+
Motion
Control
Division
!DANGER!
HIGH VOLTAGE
P/N
Dimensions - Millimeters [Inches]
Figure 3-1.
Aerotech, Inc.
rrier.
ba
BA
SERVO
AMPLIFIER
@ www.aerotechinc.com
13
1
CONTROL INTERFACE P1
25
14
S/N
BA Amps Side View
Technical Details
4.4 [.17]
TYP.
4.8 [.19]
TYP.
69.9 [2.75]
1FT
3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ba20 seriesBa30 series

Table of Contents