Rack Installation - Agilent Technologies N8700 User Manual

System dc power supply
Table of Contents

Advertisement

2 Installation

Rack Installation

CAUTION
Cleaning
WARNING
18
Ensure that the screws used to attach the rack slide kit do not penetrate more
than 6 mm into the sides of the unit.
Do not block the air intake at the front, or the exhaust at the rear of the unit.
The Agilent N8700 power supplies can be mounted in a standard 19-
inch rack panel or cabinet. They are designed to fit in two rack units
(2U) of space. To install the power supply in a rack:
1. Use the front panel rack-mount brackets to install the power
supply in the rack.
2. Use a support bracket to provide adequate support for the rear of
the power supply.
3. Rack mount slides can be attached to the unit when installing the
unit in a standard 19-inch equipment rack. Use the Agilent N5740A
Rack-Mount Slide Kit and refer to the following figure for assembly
instructions. Use two #10-32 x 3/8 in (max.) screws on each side. To
prevent internal damage, use the specified screw length only.
SHOCK HAZARD To prevent electric shock, unplug the unit before cleaning.
Use a dry cloth or one slightly dampened with water to clean the
external case parts. Do not attempt to clean internally.
Series N8700 User's Guide