GAS REQUIREMENTS

LP TANK REQUIREMENTS

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. Never
use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for
LP gas cylinders of the U.S. Department of Transportation (DOT) and designed for use with a
Type 1 system only.
Do not change the regulator/hose assembly from that supplied with the unit or attempt to use
a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The
cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve
outlet specified, as applicable, for connection Type 1.
If the appliance is stored indoors, the cylinder must be disconnected and removed from the
appliance.
Cylinders must be stored outdoors in a well ventilated area out of the reach of children.
Gas must be turned off when not in use.