Matrix Output - ALLEN & HEATH GL4800 User Manual

Professional dj mixer
Hide thumbs Also See for GL4800:
Table of Contents

Advertisement

R
LOCAL
METERPOD
4
3
2
1
MTX
AUX8
7
6
5
R
L
2
2
AUX10
9
FOR MATRIX/LR2 ON XLR + INSERTS =
SEND
SEND
SEND
SEND
SEND
SEND
SEND
SEND
INSERT
INSERT
INSERT
INSERT
INSERT
INSERT
INSERT
INSERT
RET
RET
RET
RET
RET
RET
RET
RET
AUX
AUX
10
9
R2
MONITOR 10
MONITOR 9
2-TRACK
RETURN
L
R
RESET
IN
MIDI
THRU
OUT
CHASSIS
GROUND
A
B
DC POWER IN
(MAIN)
(BACKUP)
16
Meterpod Connector
L
Recessed 16-pin dual row header for connection to the meterpod.
Local Stereo Monitor
MATRIX
For connection to a stereo amplifier/speaker system for LR, AFL/PFL
monitoring local to the console.
OUT2
MODE
3-pole 1/4" jack sockets (tip = hot). Impedance matched 50ohm 0dBu
OUT REV
nominal line level.
Headphones
Connections for 2 stereo headphones >8ohms. One connector is on the
front panel, the other is concealed under the armrest.
L2
3-pole 1/4" jack sockets (tip = left, ring = right).

Matrix Output

3-pole 1/4" jack socket (tip = hot). Impedance balanced 50ohm 0dBu
nominal line level.
Can swap with the aux output XLRs and inserts to drive long cable runs
without loss or interference, and to insert external signal processing devices
such as graphic equalisers and delays.
LR2 Output
Secondary LR output for 2-track recording, broadcast or additional speaker
and zone feeds.
3-pole 1/4" jack socket (tip = hot). Impedance balanced 50ohm 0dBu
nominal line level.
Can swap with the aux output XLRs and inserts to drive long cable runs
without loss or interference, and to insert external signal processing devices
such as graphic equalisers and delays.
2-Track Return Input
For connection to 2-track playback equipment such as cassette, DAT or CD
players.
3-pole 1/4" jack sockets (tip = signal). Unbalanced 50ohm. +10dB
maximum gain allows connection to low and high level equipment.
MIDI Interface
Standard 5-pin 180' connectors for opto-isolated connection to other MIDI
equipment. A mute processor reset switch is provided.
Console DC Power Input
INSERT
INSERT
INSERT
INSERT
The console connects to a separate power supply unit via a 10-pin circular
connector cable. Connect only the Allen & Heath power unit supplied with
the console. The standard power supply is the RPS11. Plug in a second
RPS11 if a redundant backup is required.
A chassis ground terminal post is provided. This connects to mains earth
through the power cable.