Grizzly G0562Z Owner's Manual page 29

Grizzly dust collector user manual
Hide thumbs Also See for G0562Z:
Table of Contents

Advertisement

Be sure that you extend the bare copper wire
down all branches of the system. Do not forget
to connect the wires to each other with wire nuts
when two branches meet at a "y" or "t" connec-
tion.
Ensure that the entire system is grounded. if using
plastic blast gates to direct air flow, the ground-
ing wire must be jumped (figure 44) around the
blast gate without interruption to the grounding
system.
plastic Blast
gate
Copper
ground Wire
figure 44. ground jumper wire when using
plastic blast gates and metal duct.
Model g0562z/zp, g1030z2/z2p (Mfg. 11/11+)
We also recommend wrapping the outside of all
plastic ducts with bare copper wire to ground the
outside of the system against static electrical build
up. Wire connections at y's and t's should be
made with wire nuts.
attach the bare ground wire to each stationary
Metal Duct
woodworking machine and attach to the dust
collector frame with a ground screw as shown in
figure 45. Ensure that each machine is continu-
ously grounded to the grounding terminal in your
electric service panel.
External ground Wire
internal ground
Wire
Flex-hose
figure 45. Flex-hose grounded to machine.
ground screw
-27-