E. Valve Access
The gas valve can be accessed behind the cement
refractory panel on the right side of the fi replace.
Lift doors out and set aside. There is a washer under each
door. Be careful not to loose those washers.
Washer
Figure 6.1
Lift Out Doors
Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
Remove two screws on side of pilot shield and remove
shield.
Figure 6.2
Remove Pilot Shield
Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
Figure 6.3
Loosen Refractory Retaining Strip
12
Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B • 4036-909 Rev C • 07/06
Remove the inside valve access panel by lifting it up and
out.
Figure 6.4
Remove Valve Access Panel
Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Figure 6.5
Remove Exterior Valve Access Panel
Use a manometer on the lower out pressure tap. Start
up the fi replace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.
Figure 6.6
Connect Manometer