ACTi TCM-5001 Hardware User Manual

H.264 poe box camera dc 12v / poe

Advertisement

Quick Links

TCM-5001
H.264 IP PoE Box Camera
Hardware User's Manual
(DC 12V / PoE)
Ver. 2012/3/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCM-5001 and is the answer not in the manual?

Questions and answers

Summary of Contents for ACTi TCM-5001

  • Page 1 TCM-5001 H.264 IP PoE Box Camera Hardware User’s Manual (DC 12V / PoE) Ver. 2012/3/14...
  • Page 2: Table Of Contents

    TCM-5001 Hardware User’s Manual Table of Contents Precautions Introduction Package Contents ................4 Features and Benefits ..............5 Safety Instructions ................7 Physical description ................ 9 Basic Connections ................. 13 Product Specification ..............14 Accessing Camera If you have DHCP server / router in your network: ...... 15 If you do have DHCP server / router in your network: ..
  • Page 3: Precautions

    TCM-5001 Hardware User’s Manual 0. Precautions Read these instructions You should read all the safety and operating instructions before using this product. Heed all warnings You must adhere to all the warnings on the product and in the instruction manual. Failure to follow the safety instruction given may directly endanger people, cause damage to the system or to other equipment.
  • Page 4: Introduction

    TCM-5001 Hardware User’s Manual 1. Introduction Package Contents TCM-5001 Camera Product CD Terminal Blocks for Power & DI/O Warranty Card Accessory *For the mounting block, please attach it flat side to the front. There are two types of mounting blocks, and this device uses the white version.
  • Page 5: Features And Benefits

    TCM-5001 Hardware User’s Manual Features and Benefits This is a cutting-edge digital video surveillance camera. It can compress and transmit real time images with outstanding image quality (30 FPS @ VGA 640x680) through a standard TCP/IP network. This camera is your best choice to build an intelligent IP surveillance system.
  • Page 6 TCM-5001 Hardware User’s Manual software developers. Software developers can save considerable efforts by using our Streaming Library or ActiveX control. Please contact us for details on integration support. Digital Time Code Embedded The “Digital Time Code Embedded” function records video time in the video stream. Therefore, each image frame is marked with its original recording time.
  • Page 7: Safety Instructions

    TCM-5001 Hardware User’s Manual Safety Instructions Don’t use the power supply with other voltages This device is likely to be damaged or damage other equipments / personnel, if you use a power supply with different voltage than the one included with this device. All warranty of this product will be voided in the situations above.
  • Page 8 TCM-5001 Hardware User’s Manual this manual. Adjust only those controls that are covered by the instruction manual, as an improper adjustment of other controls may result in damage, and will often require extensive work by a qualified technician to restore the video product to its normal operation.
  • Page 9: Physical Description

    TCM-5001 Hardware User’s Manual Physical description 1) Ethernet Port The IP device connects to the Ethernet via a standard RJ45 connector. Supporting NWAY, this IP device can auto detect the speed of local network segment (10Base-T/100Base-TX Ethernet). 2) Reset Button Step 1: Switch off IP device by disconnecting the power cable Step 2: Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.)
  • Page 10 TCM-5001 Hardware User’s Manual LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for another second and turn off again. By this time the reset to default operation is already completed. This will take around 20 seconds from power up.
  • Page 11 TCM-5001 Hardware User’s Manual 100mA. Pin 3 Digital Input Connect to GND to activate, or leave floating Must not be exposed to (or unconnected) to deactivate. voltages greater than 30V DC. Pin 4 Transistor Uses an open-collector NPN transistor with Max load = <100mA...
  • Page 12 TCM-5001 Hardware User’s Manual 5) Power Input Connect the power adaptor here if your power input is DC12V. NAME DESCRIPTION DC Power Input Ground Pin 6) DC Iris DC Iris Lens Control Port www.acti.com...
  • Page 13: Basic Connections

    TCM-5001 Hardware User’s Manual Basic Connections Follow the procedures below to connect the IP device to the respective apparatuses. If you have a PoE(Power over Ethernet) supported switch or injector: 1) Connect your H.264 IP PoE Box Camera to the Switch / Injector by CAT5 or CAT6 cables with RJ45 connector.
  • Page 14: Product Specification

    TCM-5001 Hardware User’s Manual Product Specification TCM-5001 Device Micron Progressive Scan CMOS Image Size 1/3 inch Effective Pixels 640 (H) x 480(V) Color 0.5 Lux at F1.0 (2400 °K, 30 IRE) Min. scene Illumination IR Sensitivity CDS Sensor Lens Mount...
  • Page 15: Accessing Camera

    TCM-5001 Hardware User’s Manual 2. Accessing Camera If you have DHCP server / router in your network: Many network server / routers are able to automatically provide IP addresses through DHCP. If you are using such a network, just plug in your computer and IP Box Cam into the network and your IP device will acquire network address by itself.
  • Page 16 TCM-5001 Hardware User’s Manual Please set the settings as below.   IP address: 192.168. 0.xxx  Subnet mask: 255.255.255. (NOTE: xxx should be a number from 1 to 254 except 100, which is used by the IP device. Please also...
  • Page 17 TCM-5001 Hardware User’s Manual If you are using a single camera, this is enough to access the device. If you are using multiple devices, you need to change the current device to another unused IP address, so that when the next device is connected to the network, no two devices use the same IP.
  • Page 18 TCM-5001 Hardware User’s Manual 10. Click “Apply” 11. Please go to Maintain -> Save & Reboot, and click ”Apply”. Internet Explorer will close after a few seconds. This is normal. 12. Wait for 30 seconds, and open IE again to connect to the IP.
  • Page 19 TCM-5001 Hardware User’s Manual www.acti.com...

Table of Contents