Colorcon™ Setup - Chauvet COLORado 3P User Manual

Table of Contents

Advertisement

COLORcon™ setup
1.
2.
Single Row
Application
SET
UP
DOWN
EXIT
Repeat Row Block Application
ID Address: 01
ID Address: 02
ID Address: 01
ID Address: 02
ID Address: 01
ID Address: 02
The figure above shows 9 fixtures connected
in series. Three rows comprised of 3 fixtures
are addressed identically. Each fixture has {ID
ON} in the fixture's settings. You must set the
{Range} settings in the controller to [003]
before accessing {Effect} programs.
COLORado™ 3 User Manual
FIXTURE CONTROL PANEL SETUP
Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON.
{MENU} Ü {Settings) Ü {ID ON/OFF} Ü [ON]
Set ID addresses in each fixture by setting panel function {ID address} to incremental
values. (I.e. 1,2,3,4,5,6,etc...)
{MENU} Ü {Settings} Ü {ID address} Ü [01 ~ 66]
It is not necessary to set the DMX address.
CONTROLLER SETUP
When using the {Effect program} function, it is necessary to set the {Settings} Ü {Range}
setting, which is the quantity of fixtures in series.
{MENU} Ü {Settings} Ü {Range} Ü [ (No. of fixtures) ]
ID Address: 01
ID Address: 02
The figure above shows 6 fixtures connected in series with corresponding
addresses. Each fixture has {ID ON} in the fixture's settings. You must set the
{Range} settings in the controller to [006] before accessing {Effect}
programs.
ID Address: 03
ID Address: 03
ID Address: 03
SET
UP
DOWN
EXIT
ID Address: 03
ID Address: 04
Block Application
ID Address: 01
ID Address: 02
ID Address: 04
ID Address: 05
ID Address: 07
ID Address: 08
The figure above shows 9 fixtures
connected in series with
corresponding addresses. Each
fixture has {ID ON} in the fixture's
settings. You must set the {Range}
settings in the controller to [009]
before accessing {Effect} programs.
16
Operating Instructions
ID Address: 05
ID Address: 06
ID Address: 03
ID Address: 06
ID Address: 09
SET
UP
DOWN
EXIT
1/30/2012 10:56 AM

Advertisement

Table of Contents
loading