To Remove Main Burner
1.
Disconnect the thermocouple and pilot supply line at the pilot
burner.
2.
Unscrew the nut on the orifice fitting union. Orifice fitting is
threaded into the main burner.
3.
Remove screw on each side of the main burner and lift out.
To Remove Main Burner Orifice
1.
Unscrew the nut on the orifice fitting union. Orifice fitting is
threaded into the main burner.
2.
Unthread the orifice fitting from the main burner.
3.
Main burner orifice is located at the end of the orifice fitting.
4.
Remove main burner orifice from orifice fitting with a 1/2"
(13mm) wrench.
1. Impossible to light pilot
a.
If using piezo ignitor, check electrode location.
b.
Remove nut at orifice and check for gas.
c.
If gas available, check for blocked orifice or pilot.
2. Pilot outage
a.
Proper size of pilot flame.
b.
Defective or weak thermocouple.
3. Pilot flames but goes out when knob is released
a.
Pilot flame not covering the thermocouple properly.
b.
Defective thermocouple.
c.
Defective magnet in the safety section of valve.
4. Poor thermostat control
a.
Thermostat needs calibrating.
b.
Defective thermostat section.
5. Noisy blower
a.
Tighten blower screws.
b.
Check blower wheel in the open for balance.
6. Yellow main burner flame
a.
Remove main burner to check for obstructions in throat,
ports and orifices.
b.
Install new main burner orifice and pilot orifice.
c.
Check gas valve for leaking.
d.
Open the air shutter on the main burner in order to increase
the amount of primary air.
12821-10-1011

MAINTENANCE

Cleaning Combustion Chamber
A qualified serviceman should remove the chamber and apply air
pressure to the inside in order to clear all passageways.

TROUBLESHOOTING

7. Yellow pilot flame
8. Pilot and main burner goes out after burning a few min-
9. Burner flashes- back or "pops" and burns at main burner
10. Inoperative blower
a.
Small yellow tip not objectionable.
b.
Remove pilot orifice. Check and clean.
utes
a.
Improper venting of flue products. Relight and check for
improper venting.
b.
If vented properly, check vent safety switch, replace if
defective.
orifice
a.
Examine main burner for defects.
a.
Check fan control by shorting across terminals.
b.
Check for blower wheel bind by removing wheel and op-
erating motor.
c.
Check for frozen bearings due to lack of oil.