Advertisement

Installer: Please leave these instructions with
the consumer.
Consumer: Please retain these instructions
for future use.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
16009-1-0504

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
SR-30T SHOWN
AND
UNVENTED
ROOM HEATER
MODELS
SR-10T-3 SR-18T-3 SR-30T-3
EFFECTIVE DATE
MAY 2004
This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate com-
bustion and ventilation air must be pro-
vided. Refer to page 6.
WARNING: If not installed, operated and
maintained in accordance with the manu-
facturer's instructions, this product could
expose you to substances in fuel or from
fuel combustion which can cause death or
serious illness.
WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas
combustion. An unvented room heater
produces approximately one (1) ounce
(30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to
page 6.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems SR-10T-3

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER'S MANUAL UNVENTED ROOM HEATER MODELS SR-10T-3 SR-18T-3 SR-30T-3 SR-30T SHOWN Installer: Please leave these instructions with the consumer. EFFECTIVE DATE MAY 2004 Consumer: Please retain these instructions for future use. This is an unvented gas-fired heater. It WARNING: If the information in this uses air (oxygen) from the room in which manual is not followed exactly, a fire or...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ........................3 Safety Information for Users of LP Gas ..................... 4 Introduction ..............................5 Specifications ............................. 5 Water Vapor: A By-Product of Unvented Room Heaters ................6 Provisions for Adequate Combustion and Ventilation Air ................. 6 Gas Supply ..............................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • An unvented room heater having an input rating of • Installation and repair should be done by a QUALIFIED more than 6,000 Btu per hour shall not be installed in a SERVICE PERSON.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS by point with the members of your household. Someday Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone's safety will depend on knowing exactly what to do.
  • Page 5: Introduction

    INTRODUCTION Instructions to Installer Important 1. Installer must leave instruction manual with owner after All correspondence should refer to complete Model Number, installation. Serial Number and type of gas. 2. Installer must have owner fill out and mail warranty card Well Head Gas Installations supplied with unvented room heater.
  • Page 6: Water Vapor: A By-Product Of Unvented Room Heaters

    WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented The following steps will help insure that water vapor does not room heater produces approximately one (1) ounce (30ml) of become a problem. water for every 1,000 BTU's (.3KW's) of gas input per hour.
  • Page 7: Gas Supply

    GAS SUPPLY The gas line can be routed either through the floor or wall. The gas A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required line opening should be made at this time.
  • Page 8: Sr-10T Clearances

    SR-10T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. 12" MAX Left side 6 inches (152mm). Right side 6 inches (152mm). (305mm) Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). 24 "...
  • Page 9: Sr-18T Clearances

    SR-18T CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). 36"...
  • Page 10: Wall Mount Installation

    WALL MOUNT INSTALLATION Refer to Figures 7, 8 and 9 for measurements in order to locate (4) 24 1/8" mounting holes on wall. Figures 7, 8 and 9 are the front views of (613mm) the heaters. 20 1/8" 2" 2" 1.
  • Page 11: Optional Floor Stand Installation

    4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •...
  • Page 13: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) 8. Inspect main burner orifice(s) through the rectangular The main burner flame will have a red-orange glow over the opening(s) in the venturi (throat) of the main burner(s). Dust, surface of the ceramic plaques.
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct flame will be blue and will extend beyond the 2. Blow air pressure through the holes indicated by the arrows. thermocouple. The flame will surround the thermocouple just This will blow our foreign materials such as dust, lint and below the tip.
  • Page 15: Appliance Maintenance

    APPLIANCE MAINTENANCE 5. Remove upper louver from casing assembly (2 screws). Removing Pilot/Thermocouple From Main Burner 6. If installed, remove optional blower assembly (4 screws). Assembly 7. Disconnect inlet supply tubing, outlet supply tubing, pilot Attention: The thermocouple CAN NOT be replaced as an supply tubing and thermocouple lead from gas valve.
  • Page 16: Troubleshooting

    TROUBLESHOOTING 1. Spark electrode does not produce spark. b. INTERLOCK latching device is operative - see "Lighting a. Spark electrode broken - replace. Instructions," Page 12, Step 9. b. Ignitor wire may not be attached to spark electrode - c. Thermocouple not tightened into gas control - tighten attach.
  • Page 17: Sr-18T And Sr-30T Parts List

    PARTS LIST SR-30T SR-18T PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART NUMBER NUMBER DESCRIPTION NUMBER NUMBER DESCRIPTION 13348 CASING SIDE ASSEMBLY - LEFT 13348 CASING SIDE ASSEMBLY - LEFT SR-041 CASING BACK SR-090...
  • Page 18: Sr-10T Parts View

    PARTS VIEW SR-10T Page 18 16009-1-0504...
  • Page 19: Sr-18T Parts View

    PARTS VIEW SR-18T 16009-1-0504 Page 19...
  • Page 20: Sr-30T Parts View

    PARTS VIEW SR-30T Page 20 16009-1-0504...
  • Page 21: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION ISNTRUCTIONS SRB-18T and SRB-30T for Unvented Room Heaters SR-18T and SR-30T INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T 12. With the heater standing upright, position the air discharge opening If heater is installed onto the wall, in order to install the optional of the blower housing downward.
  • Page 22 OPTIONAL BLOWER INSTALLATION ISNTRUCTIONS (continued) Wiring The appliance, when installed, must be electrically grounded in accor- dance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong...
  • Page 23: Service Notes

    SERVICE NOTES 16009-1-0504 Page 23...
  • Page 24 PH: 1-800-851-3153 Empire Comfort Systems, Inc. FAX: 1-800-443-8648 Nine Eighteen Freeburg Ave. E-MAIL: info@empirecomfort.com Belleville, Illinois 62222-0529 WEB SITE: www.empirecomfort.com Page 24 16009-1-0504...