Empire Heating Systems SR-10TW-1 Installation Instructions And Owner's Manual

Empire Heating Systems SR-10TW-1 Installation Instructions And Owner's Manual

Unvented room heater

Advertisement

Quick Links

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
SR-30TW SHOWN
UNVENTED
ROOM HEATER
MODELS
SR-10TW-1
SR-18TW-1
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
WARNING
"FIRE, EXPLOSION, AND ASPHYXIATION HAZARD
Improper adjustment, alteration, service,
maintenance, or installation of this heater or
its controls can cause death or serious injury.
Read and follow instructions and precautions
in User's Information Manual provided with
this heater."
This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilation air must be
provided. Refer to page 6.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion.
An unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 6.
SR-30TW-1
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems SR-10TW-1

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEATER MODELS SR-10TW-1 SR-18TW-1 SR-30TW-1 WARNING SR-30TW SHOWN If not installed, operated and maintained in accordance with the manufacturer’s INSTALLER: instructions, this product could expose you Leave this manual with the appliance. to substances in fuel or from fuel combustion which can cause death or serious illness.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ............................. 3 Safety Information for Users of Propane Gas ......................4 Introduction ................................5 Specifications ................................5 Water Vapor: A By-Product of Unvented Room Heaters ................... 6 Provisions for Adequate Combustion and Ventilation Air ..................6 Gas Supply ................................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPeRATe THIS APPLIANCe WITHOUT FRONT PANeL INSTALLeD. • Due to high surface temperatures, keep children, clothing DANGER: Indicates a hazardous situation which, if not and furniture away. avoided, will result in death or serious injury. •...
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- members of your household. Someday when there may not sions. In its natural state, propane is odorless and colorless. be a minute to lose, everyone’s safety will depend on knowing You may not know all the following safety precautions which exactly what to do.
  • Page 5: Introduction

    INTRODUCTION Instructions to Installer Qualified Installing Agency 1. Installer must leave instruction manual with owner after Installation and replacement of gas piping, gas utilization equipment installation. or accessories and repair and servicing of equipment shall be 2. Installer must have owner fill out and mail warranty card supplied performed only by a qualified agency.
  • Page 6: Water Vapor: A By-Product Of Unvented Room Heaters

    WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room The following steps will help insure that water vapor does not heater produces approximately one (1) ounce (30ml) of water for become a problem.
  • Page 7: Gas Supply

    GAS SUPPLY the National Fuel Gas Code that a drip line be installed near the gas The gas line can be routed either through the floor or wall. The gas inlet. This should consist of a vertical length of pipe tee connected line opening should be made at this time.
  • Page 8: Sr-10Tw Clearances

    SR-10TW CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm).
  • Page 9: Sr-18Tw Clearances

    SR-18TW CLEARANCES When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm).
  • Page 10: Wall Mount Installation

    WALL MOUNT INSTALLATION Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views (613mm) of the heaters. (511mm) (51) (51) 1. Remove lower louver from casing assembly (2 screws). 2.
  • Page 11: Optional Floor Stand Installation

    4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand. C.
  • Page 13: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS SR-10TW, SR-18TW and SR-30TW Main Burner Flame. See Disconnect supply tubing from orifice holder(s). Figure 12. The main burner flame will have a red-orange glow over 10. Remove orifice holder from venturi of main burner assembly the surface of the ceramic plaques.
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct flame will be blue and will extend beyond the thermo- Blow air pressure through the holes indicated by the arrows. couple. The flame will surround the thermocouple just below the This will blow our foreign materials such as dust, lint and spider tip.
  • Page 15: Appliance Maintenance

    APPLIANCE MAINTENANCE Remove reflector from casing assembly (2 screws). Removing Pilot/Thermocouple From Main Burner Assembly Remove upper louver from casing assembly (2 screws). Attention: The thermocouple CAN NOT be replaced as an individual If installed, remove optional blower assembly (4 screws). item.
  • Page 16: Sr-10Tw Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. SR-10TW SR-10TW INDEX PART INDEX PART DESCRIPTION DESCRIPTION 39818 CASING SIDe ASSeMBLY - LeFT SR-179 PILOT BRACKET (NATURAL) 39911 CASING BACK SR-032 PILOT BRACKET (PROPANE) R-2313...
  • Page 17: Sr-10Tw Parts View

    SR-10TW PARTS VIEW 39909-0-0918 Page 17...
  • Page 18: Sr-18Tw Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. SR-18TW SR-18TW INDEX PART INDEX PART DESCRIPTION DESCRIPTION 39819 CASING SIDe ASSeMBLY - LeFT OPTIONAL BLOWER KIT SRB-18TW (INCLUDES 30 THROUGH 37) 39822 CASING BACK R-1454...
  • Page 19: Sr-18Tw Parts View

    SR-18TW PARTS VIEW 39909-0-0918 Page 19...
  • Page 20: Sr-30Tw Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. SR-30TW SR-30TW INDEX PART INDEX PART DESCRIPTION DESCRIPTION 39819 CASING SIDe ASSeMBLY - LeFT R-1992 BULB CLIP 39823 CASING BACK OPTIONAL SRS-30 FLOOR STAND SR-115 R-2313 PIeZO IGNITOR...
  • Page 21: Sr-30Tw Parts View

    SR-30TW PARTS VIEW 39909-0-0918 Page 21...
  • Page 22: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS SRB-18TW and SRB-30TW for Unvented Room Heaters SR-18TW and SR-30TW INSTALLING OPTIONAL BLOWER SRB-18TW OR SRB-30TW 12. With the heater standing upright, position the air discharge If heater is installed onto the wall, in order to install the optional opening of the blower housing downward.
  • Page 23 oPTIonAL BLoWER InSTALLATIon InSTRUCTIonS (ConT’D) Wiring The appliance, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [ground- ing] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 24: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 25: Warranty

    WARRANTY TERMS empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 26: Appliance Service History

    APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 26 39909-0-0918...
  • Page 27 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 39909-0-0918 Page 27...
  • Page 28 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 28 39909-0-0918...

This manual is also suitable for:

Sr-18tw-1Sr-30tw-1Sr-30twSr-10twSr-18tw

Table of Contents