WARNING: If the information in these in-
structions are not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vi-
cinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
AND
VENTED
ROOM HEATER
MODELS
RH-25-6
RH-35-6
Installer:
Leave this manual with the ap-
pliance.
Consumer: Retain this manual for future
reference.
WARNING: If not installed, operated and
maintained in accordance with the manu-
facturer's instructions, this product could
expose you to substances in fuel or from
fuel combustion which can cause death
or serious illness.
Page 1

Advertisement

loading

Summary of Contents for Empire Heating Systems RH-25-6

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER’S MANUAL VENTED ROOM HEATER MODELS RH-25-6 RH-35-6 Installer: Leave this manual with the ap- WARNING: If the information in these in- pliance. structions are not followed exactly, a fire Consumer: Retain this manual for future or explosion may result causing property reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ....................... 3 Safety Information for Users of LP Gas ..................4 Introduction ..........................5 Specifications ..........................5 Gas Supply..........................6 Clearances ..........................7 Venting ............................7 Vent Safety Shutoff System ....................... 8 Reversible Vertical or Horizontal Diverter ...................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures, the room heater should control compartments, burners and circulating air be located out of traffic and away from furniture passageways of the room heater be kept clean.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone's safety colorless.
  • Page 5: Introduction

    INTRODUCTION Introduction be installed on a metal or wood panel extending the full width and Always consult your local Building Department regarding regula- depth of the appliance. tions, codes or ordinances which apply to the installation of a vented The base referred to above does not mean the fire-proof base as room heater.
  • Page 6: Gas Supply

    GAS SUPPLY to the action of liquefied petroleum gases. The gas lines must be Recommended Gas Pipe Diameter checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if Pipe Length Schedule 40 Pipe Tubing, Type L...
  • Page 7: Clearances

    CLEARANCES Clearances: When facing the front of the room heater the mini- heater permitted within 48 inches (122cm). mum clearances to combustible construction (material) are the Ceiling 48 inches (122cm). Rear of draft hood 2 inches (51mm). following: Open in front to provide service, access, and clearance to com- Right side 6 inches (152mm).
  • Page 8: Vent Safety Shutoff System

    VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This safety switch will cause gas flow to the pilot to “shut off” due to heater is equipped with a vent safety shutoff system. improper venting or a blocked flue. If the vent safety switch continues to “shut off”...
  • Page 9: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance has a pilot which must be lighted by hand. partment.
  • Page 10: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting when the inlet pressure is above 5"...
  • Page 11: Maintenance

    MAINTENANCE To Remove Main Burner Cleaning Combustion Chamber Disconnect the thermocouple and pilot supply line at the pilot A qualified serviceman should remove the chamber and apply air burner. pressure to the inside in order to clear all passageways. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner.
  • Page 12: Parts List

    PARTS LIST INDEX PART DESCRIPTION INDEX PART DESCRIPTION NUMBER NUMBER 11704 Inner Casing Assembly (RH-25-6) (USA) R-6096 Knob & Adaptor Set 15672 Inner Casing Assembly (RH-25-6) (Canada) 11700 Control Rod Bracket 11701 Inner Casing Assembly (RH-35-6) (USA) R-2706 ECO Switch...
  • Page 13: Parts View

    PARTS VIEW 12821-10-1011 Page 13...
  • Page 14: Optional Blower Installation Instructions

    OPTIONAL BLOWER INSTALLATION INSTRUCTIONS DRB-1 For Vented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Direct Vent Wall Furnaces DV-25-(1, 2)SG and DV-35-(1, 2)SG Installing Optional DRB-1 Blower For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6), remove casing front.
  • Page 15 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 16: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 17: Appliance Service History

    APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 12821-10-1011 Page 17...
  • Page 18 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 18 12821-10-1011...
  • Page 19 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 12821-10-1011 Page 19...
  • Page 20 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com Page 20 12821-10-1011...
  • Page 21 INSTRUCTIONS POUR L’INSTALLATION MANUEL DU PROPRIÉTAIRE RADIATEUR INDIVIDUEL À AIR PULSÉ MODÈLES RH-25-6 RH-35-6 AVERTISSEMENT: Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
  • Page 22 TABLE DES MATIÈRES SECTION PAGE Information Importante de Sécurité ..................3 Information de Sécurité pour les Utilisateurs de Propane ............4 Introduction ..........................5 Spécifications..........................5 Alimentation en Gaz .......................6 Espaces Libres ........................7 Évacuation ..........................7 Le Système de Fermeture de Sûreté de l’Évent ..............8 Coupe-Tirage Réversible Soit Vertical ou Horizontal ............8 Fonctionnement du Thermostat ....................8 Instructions d'Allumage ......................9...
  • Page 23: Information Importante De Sécurité

    INFORMATION IMPORTANTE DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LA PAROI FRONTALE SOIT INSTALLÉE. • A cause des hautes températures, cet appareil doit être situé propres. dans un endroit non achalandé et loin des meubles et des •...
  • Page 24: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des puis réexaminez les, point par point avec les membres de votre explosions. Dans son état naturel, le propane est inodore et sans famille.
  • Page 25: Introduction

    INTRODUCTION Installation sur un Tapis ou Tuile Introduction Si cet appareil est installé directement sur un tapis, tuiles ou tout genre de Toujours consulter le département de construction de votre région en ce matériel combustible autre qu’un plancher de bois, cet appareil doit être qui regarde les règlements, les codes ou les ordonnances qui s’appliquent installé...
  • Page 26: Alimentation En Gaz

    ALIMENTATION EN GAZ Les composantes employées sur les joints filetés des tuyaux doivent être Le Diamètre recommandé de tuyau de gaz résistantes à l’action des gaz de pétrole liquéfiés. La canalisation de gaz Longuer de Le plan 40 tuyau Les tuyaux, Taper L doit être vérifiée par l’installateur pour des possibilités de fuites.
  • Page 27: Espaces Libres

    ESPACES LIBRES Côté droit 6" (15.2cm) Côté gauche 6" (15.2cm) Espaces libres: Lorsque vous êtes devant le radiateur individuel, les espaces Pour l’entretien, nous recommendons 18" (45.6cm) pour le côté gauche. libres minimum aux matériaux combustibles sont les suivants: Ne pas installer dans une niche ou un placard. Aucune saillie horizontale est permise 48"...
  • Page 28: Le Système De Fermeture De Sûreté De L'évent

    LE SYSTÈME DE FERMETURE DE SÛRETÉ DE L’ÉVENT Cet appareil doit être branché correctement à un système d’évacuation. Cet Ce radiateur individuel est muni d’un interrupteur de sûreté de l’évent. appareil est muni d’un système de fermeture de sûreté de l’évent. Lors d’une évacuation inadéquate ou d’une obstruction de la cheminée, l’interrupteur de sûreté...
  • Page 29: Instructions D'allumage

    INSTRUCTIONS D'ALLUMAGE POUR VOTRE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuellement. •...
  • Page 30: Aspect Convenable De La Flamme De La Veilleuse

    ASPECT CONVENABLE DE LA FLAMME DE LA VEILLEUSE La flamme sera quasiment horizontale, bleue et s’allongera au-delà du thermocouple de 1/4" (6mm). La flamme entourera le thermocouple juste LA FLAMME DOIT SE PROLONGER en-dessous de la pointe. AU-DELÀ DU THERMOCOUPLE Avec du gaz propane (LP-gaz), un jaune pâle apparaîtra à...
  • Page 31: Maintenance

    MAINTENANCE Enlever le Brûleur Principal Nettoyage de la Chambre de Combustion Du brûleur de la veilleuse, débrancher le thermocouple et la ligne Un technicien d’entretien qualifié devrait enlever la chambre et appliquer d’alimentation de la veilleuse. une pression d’air à l’intérieur de façon à nettoyer tous les passages. Dévisser l’écrou sur le raccord de l’orifice.
  • Page 32: Façon De Commander Les Pièces De Réparation

    ORIFICE DU BRÛLEUR PRINCI- PAL EN CUIVRE (RH-35-6 LPG) RH-682 PAROI AVANT (USA) P-86-54 ORIFICE DU BRÛLEUR PRINCI- 15671 PAROI AVANT (CANADA) PAL EN CUIVRE (RH-25-6 LPG) RH-737 BRÛLEUR (RH-25-6) P-269 ASSEMBLAGE DU TUYAU DE RH-738 BRÛLEUR (RH-35-6) R-1195 THERMOCOUPLE 36"...
  • Page 33: Vue Des Pièces

    VUE DES PIÈCES ISOLATION SEULEMENT POUR RH-35-6 ISOLATION 12821-11-1011 Page 13...
  • Page 34: Instructions Pour L'installation De La Soufflerie Facultative

    INSTRUCTIONS POUR L’INSTALLATION DE LA SOUFFLERIE FACULTATIVE DRB-1 Radiateur Individuel à Air Pulsé RH-25-(1, 2, 4, 5, 6) et RH-35-(1, 2, 4, 5, 6) Radiateurs Muraux à Évacuation Directe DV-25-(1, 2)SG et DV-35-(1, 2)SG Installation de la Soufflerie Facultative DRB-1 Pour RH-25-(1, 2, 4, 5, 6) et RH-35-(1,2, 4, 5, 6), enlever la paroi avant du radiateur.
  • Page 35 Pose des Fils Électriques L’appareil, lorsqu’il est installé, doit avoir une prise de terre con- forme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electrical Code, ANSI/NFPA70 (dernière édition) ou le CSA C22.1 CANADIAN ELECTRICAL CODE en cours. Pour votre protection contre les dangers de chocs, cet appareil est muni d’une fiche à...
  • Page 36: Notes De Service

    NOTES DE SERVICE Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre Comfort Systems revendeur.

This manual is also suitable for:

Rh-35-6