Safety Precautions

To avoid potential video and keyboard problems when using Avocent products:
If the building has 3-phase AC power, ensure that the computer and monitor are on the same
phase. For best results, they should be on the same circuit.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe the
following precautions:
Test AC outlets at the target device and monitor for proper polarity and grounding.
Use only with grounded outlets at both the target device and monitor. When using a backup
Uninterruptible Power Supply (UPS), power the target device, the monitor and the SwitchView
IP 1020 remote access device from the UPS.
NOTE: The power cord is considered the main disconnect device.
Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of circuits might have on overcurrent protection and supply wiring.
Consider equipment nameplate ratings for maximum current.
Reliable earthing of equipment should be maintained. Pay particular attention to supply
connections other than direct connections to the branch circuit (for example, use of power
strips). Reliable earthing of equipment should be maintained.
SwitchView IP 1020 Remote Access Device
Ethernet
Analog User
(Computer with Internet Browser)