Ferroli TEMPRA 24 Installation, Service And User Instructions Manual page 14

Copper wall-mounted system, gas fired boiler for central heating, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

3.03 Top Outlet Concentric Flue Connection
3.03.1 Vertical concentric connection
Concentric
Vertical
Connector
3.03.2 Horizontal concentric connection
A 90° bend (fig. 13) is supplied for the horizontal connection of air and flue gas pipes. This can be oriented
towards the chosen wall in degrees of 45°.
14
30
Ø60
95
190
270
A vertical connector can be supplied for vertical
discharge with concentric pipes.
The simple mounting and use of double lip gaskets
at the joints makes this an extremely easy and safe
option.
For flue length up to 1 m long the 50 mmØ restrictor is
required. Longer than this no restrictor is required.
Fig. 12
L
50*
125
Ø80
70
D
S
Fig. 13
Tempra 24
L = S + D + 205
* = between 10 e 60 mm
-3 mm/m
80
70 min.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents