3.01 Drilling Template (Top Flue Application) (Standard Top Flue Application)
Select suitable mounting position
points. Drill two 10mm holes 70mm deep to accept the wall plugs. Fit standard wall plugs on the left and
right side and the special wall plug in the middle (fig. 10a). Fix the wall bracket to the wall using standard
lock nut (M8) on both sides. Mount the boiler on the wall bracket as described in the fig. 10a. Using a core
drill cut a 118mm diameter hole for the flue.
CH flow
1.
Gas supply
2.
CH return
3.
12
for
boiler, using the template mark flue outlet and
Ø3/4"
1
Fig. 10a
Ø118
269
125 min
280
200
165 min
21 min
Ø1/2"
Ø3/4"
2
3
Fig. 10b
Tempra 24
boiler mounting
0
1 1
5 min