Horizontal Flue Installation - Ferroli DOMIcompact F 24 B Instructions For Use, Installation And Maintenance

Wall-mounted gas fired, condensing combination boiler
Table of Contents

Advertisement

DOMIcompact F 24 B
Connection with concentric flue system
The unit can be connected to a concentric air/flue duct with a horizontal or vertical outlet as shown in
the following drawings. Numerous accessories are available on request to meet the various installation
requirements. Please refer to our "flue manual" or the price list for details .
Rear Outlet
View from above
fig. 10a

Horizontal flue installation

1. Define the Suitable position for installing the boiler(See 2.2 Boiler location) .
2. When installing a horizontal flue kit, please ensure a 3 mm per metre fall back to the appliance is incor-
porated .
3. Make a hole of diameter 10 - 20 mm greater than the nominal diameter of the concentric pipe used.
4. If necessary, cut the end pipe to size, ensuring that the external pipe protrudes from the wall by between
10 and 60 mm (Fig. 10a and 10b). Remove all cutting burrs and lubricate the seals with a suitable silicone
based grease .
Horizontal concentric flue installation
Side view
P = S + 83 mm
Side Outlet
Front view
View from above
L = S + D + 239 mm
fig. 10b
17