2.2 Boiler location

The boilers combustion chamber is sealed off from the installation room. The installation room must be
sufficiently well ventilated to prevent any dangerous conditions from forming in the event of even slight
gas leakage. This safety standard is required by the EEC Directive no. 90/396 for all gas units, including
those with a so-called sealed chamber.
Therefore the place of installation must be free of dust, flammable materials or objects or corrosive
gases. The room must be dry and not subject to freezing.
The boiler is design to be installed on a solid wall. The wall fixing must ensure a stable and effective
support for the appliance, using the bracket and fixings supplied.
If the unit is enclosed in a cupboard or mounted alongside, there must be space for normal maintenance
work. Fig. 2 and tab. 1 give the minimum clearances to leave around the unit.
This appliance does not require compartment ventilation for combustion purposes
fig. 2
Drilling Template
Select suitable mounting position for boiler, using the template mark flue outlet and boiler mounting
points. Drill two 10mm holes 70mm deep to accept the wall plugs. Fit the supplied wall plugs on the
left and right side drill and fit the special wall plug in the middle (fig. 3). Fix the wall bracket to the wall
using standard lock nuts (M8) on both sides. Using a Core drill cut a 118mm diameter hole for the flue
as detailed on page 17. Mount the boiler on the wall bracket and secure using the special antitheft nut
(M8) as described in the fig. 3.