Ferroli DOMIcompact F 24 B Instructions For Use, Installation And Maintenance page 21

Wall-mounted gas fired, condensing combination boiler
Table of Contents

Advertisement

DOMIcompact F 24 B
Statutory mininum distances for terminai siting
Opposite
boundary
A - minimum distance 600mm - may be a nuisance if it 'wets'opposite boundary, crosses
main pathway or condensate can drip on pathway.
B - minimum distance 600mm - may be a nuisance as plume could obscure window.
C - minimum distance 600mm - may be a nuisance if plumecrosses door.
The plume should not cross:
• a frequently used access route;
• any frequently used area (such as a patio or car parking space);
• a neighbouring dwelling.
Nor should it be directed towards a window or door, or be sited close to a
facing wali or other surface.
There are also other aspects to consider when planning the flue terminal position.
• A free passage of air is needed at all times to aid plume dispersal - which may be difficult in sheltered
locations.
• In cold weather, the condensate could cause a safety hazard if it freezes on pathways, or if it results in
frost damage to surfaces.
• The plume could trigger infra-red security lighting if sited in the wrong place.
• Ensure terminals do not obscure security camera field of vision.
• The terminal guards must be able to resist corrosive properties of the condensate.
A
Pathway
B
C
21