Flue System - Ferroli DOMIcompact F 24 B Instructions For Use, Installation And Maintenance

Wall-mounted gas fired, condensing combination boiler
Table of Contents

Advertisement

DOMIcompact F 24 B
Access to the electrical terminal block
To access the terminal block where the room thermostat (Low voltage) or the remote timer control is
to be connected, carry out the following operations:
1 Unscrew the two screws "A" (Fig. 8a)
2 Lower the instrument panel (Fig. 8b)
3 Turn the instrument panel (Fig. 8c)
You can now access the terminal block "B"
(Fig. 8c)

2.6 Flue system

The unit is "type C" with a sealed chamber and forced draught, the air inlet and flue outlet must be
connected to one of the following flue systems. With the aid of the tables and methods of calculation indi-
cated, before commencing installation, it is first necessary to check that the flue system does not exceed
the maximum permissible length. The current standards and local regulations must be observed.
It should be noted that only Ferroli flue system and accessories should be used on this appliance,
as per BS 5440 2000 and C.E. test certification.