Ferroli ATLAS Instructions For Use, Installation And Maintenance
Ferroli ATLAS Instructions For Use, Installation And Maintenance

Ferroli ATLAS Instructions For Use, Installation And Maintenance

Heat generator for hot water production suitable for operation with blown oil or gas burners

Advertisement

Quick Links

ATLAS
ISTRUZIONE PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
KULLANMA, KURULUM VE BAK M TALIMATLAR
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
,
AANWIJZINGEN VOOR GEBRUIK, INSTALLATIE EN ONDERHOUD
,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATLAS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ferroli ATLAS

  • Page 1 ATLAS ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO KULLANMA, KURULUM VE BAK M TALIMATLAR INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN AANWIJZINGEN VOOR GEBRUIK, INSTALLATIE EN ONDERHOUD...
  • Page 2: General Instructions

    Heating temperature setting Set the required system temperature with the control thermostat 4 of fig. 1. For the model ATLAS 95, with the control thermostat 5 then set the temperature of the 1. GENERAL INSTRUCTIONS 2nd stage to a temperature 10°C lower than that of the 1st stage.
  • Page 3: Service And Maintenance

    Service. Two shutdown conditions resettable by the user can occur : FERROLI declines any liability for damage and/or injury caused by unqualified and un- Burner shutdown signalled by the special indicator. Refer to the burner manual. authorised people tampering with the unit.
  • Page 4: Technical Data And Characteristics

    ATLAS 5. TECHNICAL DATA AND CHARACTERISTICS 5.3 Technical data table 5.1 Dimensions, connections and main components Model ATLAS 32 ATLAS 47 ATLAS 62 ATLAS 78 ATLAS 95 Number of elements Max. heating capacity 34.9 51.6 67.7 85.6 Min. heating capacity 17.0...
  • Page 5 5.4 Wiring diagram Main wiring diagram ATLAS 95 Main wiring diagram ATLAS 32-78 fig. 9 - Main wiring diagram ATLAS 95 Key fig. 9 and fig. 10 Heating circulating pump (not supplied) fig. 7 - Main wiring diagram ATLAS 32-78...
  • Page 6: Dichiarazione Di Conformità

    Dichiarazione di conformità Il costruttore: FERROLI S.p.A. Indirizzo: Via Ritonda 78/a 37047 San Bonifacio VR dichiara che questo apparecchio è conforme alle seguenti direttive CEE: • Direttiva Apparecchi a Gas 90/396 • Direttiva Rendimenti 92/42 • Direttiva Bassa Tensione 73/23 (modificata dalla 93/68) •...
  • Page 7: Déclaration De Conformité

    Déclaration de conformité Le constructeur : FERROLI S.p.A. Adresse: Via Ritonda 78/a 37047 San Bonifacio VR déclare que cet appareil est conforme aux directives CEE ci-dessous: • Directives appareils à gaz 90/396 • Directive rendements 92/42 • Directive basse tension 73/23 (modifiée 93/68) •...
  • Page 9 FERROLI S.p.A. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.it...