Room Unit Installation Procedure

1. Room unit location: The wall cradle should be located in the
main living room while giving consideration to the following points:
The place of installation should be chosen such that the
sensor can capture the room temperature as accurately as
possible without getting adversely affected by direct solar
radiation or other heat or refrigeration sources (about 1.5
meters above the floor) (Fig. 45).
There must be sufficient clearance around the unit, enabling it
to be fitted and removed.
Important : A TRV should not be fitted to the radiator in the
same room as the room sensor. If a TRV has been installed on
this radiator, the TRV must remain set open at all times,
otherwise the house holder will experience room
temperature control problems.
10.16

Outside sensor unit installation procedure

1. Outside sensor location: The outside sensor carton is illustrated
with Suitable locations and advises against locations which are
likely to give poor / false readings.
2. Avoid south facing walls; preferably choose a west to north
facing location.
3. The ideal height for the sensor is at approximately half the
height of the living space of the dwelling and no less than 2.5m off
the ground.
4. Avoid locating the sensor close to the flue terminal where the
flue plume could heat the sensor and cause the appliance to
switch off prematurely.
5. Two core "bell wire" is suitable.
6. When correctly connected and once the 'Save sensor'
procedure has been done (See Section 11.4), the outside
temperature and icon will be display on the THINK Controller
(See Section 10.12 and Fig 42).