MODEL 2805L THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the whirlpool installation are your selected fittings and electrical connections.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by American Standard. The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI).
Page 4
For electrical requirements, refer to section titled “Whirlpool Electrical Installation Instructions”. Check for availability of optional American Standard wall tiling bead (required for recess installation). Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
SPECIFICATIONS: SIDE VIEW GENERAL SPECIFICATIONS FOR LIFETIME / EVOLUTION / RENAISSANCE WHIRLPOOLS AND BATH TUBS Description Dimensions Drain / Height to L-W-H Overflow Underside of Deck: C A 1" L 1mm (7-3/") C 1-1/" 00L / V (57 mm) W 11mm (5-3/") (5 mm) Corner* B 13-3/"...
5' x 32" (MODEL 2422L / LA / V / VA) 0" (15mm) (7mm) CUT OUT IN FLOOR FOR DRAIN 5' x 36" (MODEL 2771L / LA / V / VA) 0" (15mm) CUT OUT IN FLOOR FOR DRAIN 7-1/" (11mm) DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z1.1 AND A11.1.7.
Page 7
CORNER (MODEL 6060L / V) 76-3/4" (1949mm) 54-1/2" (1384mm) 10" (254mm) 15" (381mm) 5-5/8" 7" (178mm) CUT OUT (143mm) IN FLOOR FOR DRAIN RECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2 X 13) RENAISSANCE (MODEL 2732) 60" (1524mm) (76mm) 33" (152mm) (838mm) CUT OUT IN FLOOR FOR DRAIN...
Page 8
REMINISCENCE (MODEL 2908L / LA) 330mm (13) 1mm (3) x 305mm ( X 1) 57mm FLOOR (1) CUTOUT mm REF. INTEGRAL (-1/) FITTING DECK 15mm OUTLINE OF C/L OF DRAIN OUTLET ELLISSE (MODEL 2711L) 1mm (7) (3-1/) 7mm 305mm (1) 11mm ()
Page 9
STRINGERS FRONT EDGE OF BATH MUST BE SUPPORTED BY STUD WALL OR ACCESS PANEL MUST BE LOCATED AMERICAN STANDARD ON THE SAME SIDE AS THE MOTOR. APRON KIT ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE. ACCESS PANELS NOT REQUIRED FOR BATH TUBS.
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL / BATH INSTALLATION METHOD WOOD STUD STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL SEALANT 1 x 3 (5 x 7mm) WOOD STRINGER FULL LENGTH STEEL STEEL STUD STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE SEALANT STRINGER FULL LENGTH...
Page 11
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter. .
For 6060L/V Corner Only OPERATION WARNING: Prior to operation, review the Important Safety Instructions listed at the beginning of this instruction manual. Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath.
DRAIN CONNECTION AND SYSTEM TEST Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain assembly instructions. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point "...
American Standard Limited Five (5) Year Warranty for the Renaissance Whirlpools American Standard warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance for a period of five (5) years from date of purchase so long as it is owned by the original consumer purchaser.
Page 15
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or other damages; if it was not installed in accordance with American Standard's instructions; or if it has been modified in a manner inconsistent with the product as shipped by American Standard.