Reverse-A-Clean ® (Rac) Tip - Graco 3A0149C Instructions And Parts List

Model g40 gun with rac tip
Table of Contents

Advertisement

Daily Gun Care, Flushing, and Cleaning
F
. 23
IG
13. If the diffuser was removed, trigger the gun while
you reinstall the diffuser (5) with the gun tool (30).
Tighten the diffuser securely to obtain a good seal.
Torque to 155-165 in-lb (18-19 N•m). When properly
tightened, the flange will bottom out on the gun.
14. Install the air cap retaining ring (6), air cap (21), and
spray tip (33).
F
. 24
IG
15. Dampen a soft cloth with solvent and wring-out the
excess. Point the gun down and wipe off the outside
of the gun.
F
. 25
IG
16
TI6570A
TI6568A
TI6571A
16. After cleaning the gun, lubricate the following parts
with lubricant 111265 weekly:
Trigger pivot pin (A)
Boss on both sides of the gun where the trigger
contacts the gun body (B)
Fluid needle shaft, behind trigger (C)
A
F
. 26
IG
Reverse-A-Clean
NOTE: Do not soak the RAC tip seat gasket (33a) in sol-
vent for extended periods of time or swelling may occur.
Clearing a clogged RAC tip
Release the trigger and engage the trigger lock.
ENGAGED
F
. 27
IG
B
C
TI6553A
®
(RAC) Tip
TI6581A
3A0149C