Pressure Relief Procedure

WARNING
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally. Fluid
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the Pressure Relief Procedure
whenever you:
are instructed to relieve the pressure,
stop spraying,
check or service any of the system equipment,
or install or clean the spray tips.
1. Lock the gun trigger safety.
2. Shut off the power supply to the pump. Close any
bleed-type master air valves.
3. Unlock the gun trigger safety.
4. Hold a metal part of the gun firmly to the side of a
grounded metal pail, and trigger the gun to relieve
pressure.
5. Lock the gun trigger safety.
6. Open the drain valve (required in your system),
having a container ready to catch the drainage.
7. Leave the drain valve open until you are ready to
spray again.
If you suspect that the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the steps above, very slowly loosen the
tip guard retaining nut or hose end coupling and relieve
pressure gradually, then loosen completely. Now clear
the tip or hose.

System Requirements

WARNING
Keep the wallet-sized warning card provided with
this gun with the operator at all times. The card
contains important treatment information should an
injection injury occur. Additional cards are available
at no charge from Graco Inc.
Installation/Operation
WARNING
Be sure your system has a bleed-type master air
valve (pneumatic pumps only) and a pressure drain
valve. These accessories help reduce the risk of
serious bodily injury, including fluid injection,
splashing in the eyes or on the skin, or injury from
moving parts, if you are adjusting or repairing the
pump or gun.
1. The bleed-type master air valve (air-powered
pumps only) relieves air trapped between this
valve and the pump after the air regulator is shut
off. Trapped air can cause the pump to cycle
unexpectedly.
2. The pressure drain valve assists in relieving fluid
pressure in the displacement pump, hose and gun:
triggering the gun to relieve pressure may not be
sufficient.
3. Strain the fluid you are spraying if it contains
particles which could clog the spray tip.

How to Use the Gun Trigger Safety

1. To lock the gun trigger safety, turn the latch to a
right angle with the gun body. See Fig. 1.
2. To unlock the gun trigger safety, push the latch out
and turn it parallel with the gun body.
The trigger safety is shown
in the locked position.
The trigger safety is shown
in the unlocked position.
Fig. 1